Single breath-hold non-contrast thoracic mra using highly-accelerated parallel imaging with a 32-element coil array
نویسندگان
چکیده
PURPOSE To evaluate the feasibility of performing single breathhold three-dimensional (3D) thoracic noncontrast MR angiography (NC-MRA) using highly accelerated parallel imaging. MATERIALS AND METHODS We developed a single breathhold NC MRA pulse sequence using balanced steady state free precession (SSFP) readout and highly accelerated parallel imaging. In 17 subjects, highly accelerated noncontrast MRA was compared against electrocardiogram-triggered contrast-enhanced MRA. Anonymized images were randomized for blinded review by two independent readers for image quality, artifact severity in eight defined vessel segments and aortic dimensions in six standard sites. NC-MRA and CE-MRA were compared in terms of these measures using paired sample t- and Wilcoxon tests. RESULTS The overall image quality (3.21 ± 0.68 for NC-MRA versus 3.12 ± 0.71 for CE-MRA) and artifact (2.87 ± 1.01 for NC-MRA versus 2.92 ± 0.87 for CE-MRA) scores were not significantly different, but there were significant differences for the great vessel and coronary artery origins. NC-MRA demonstrated significantly lower aortic diameter measurements compared with CE-MRA; however, this difference was not considered clinically relevant (>3 mm difference) for less than 12% of segments, most commonly at the sinotubular junction. Mean total scan time was significantly lower for NC-MRA compared with CE-MRA (18.2 ± 6.0 s versus 28.1 ± 5.4 s, respectively; P < 0.05). CONCLUSION Single breathhold NC-MRA is feasible and can be a useful alternative for evaluation and follow-up of thoracic aortic diseases.
منابع مشابه
Effectiveness of 32-element Surface Coil Array for Accelerated Volume-Targeted Breath-Hold Coronary MRA
Purpose : To compare 12 and 32-element surface coil arrays for highly accelerated coronary magnetic resonance angiography (MRA) using parallel imaging. Materials and Methods : Steady state free precession coronary MRA was performed in 5 healthy volunteers at 1.5 T whole body MR scanner using both 12 and 32-element surface coil arrays. Left anterior descending and right coronary artery data sets...
متن کاملHighly Accelerated Single Breath-Hold Coronary MRA with Whole Heart Coverage Using a Cardiac Optimized 32- Element Coil Array
T. Niendorf, C. J. Hardy, H. Cline, R. O. Giaquinto, A. K. Grant, N. M. Rofsky, D. K. Sodickson Applied Science Laboratory, GE Healthcare Technologies, Boston, MA, United States, Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States, GE Global Research Center, Niskayuna, NY, United States Purpose Clinical 3D coronary MRA (CMRA) is gener...
متن کاملA New Approach for Single breath-hold Whole Heart Coronary MRA Using Highly-Accelerated Parallel Imaging With a 32- element Coil Array
Introduction: Whole heart coronary MRA is typically performed with navigator gating because of the large data needed to achieve an isotropic spatial resolution on the order of 1-2 mm with extensive anatomic coverage (10-16 cm). Previous studies have shown that whole heart coronary MRA can be performed with either a single [1] or double [2,3] breath-hold (BH) approach using highly-accelerated pa...
متن کاملA comparison of a T1 weighted 3D gradient-echo sequence with three different parallel imaging reduction factors, breath hold and free breathing, using a 32 channel coil at 1.5 T. A preliminary study.
PURPOSE To investigate whether increasing temporal resolution with higher parallel imaging (PI) reduction factors (RF) in both breath-hold and free breathing approaches, using a non-contrast T1-weighted 3D gradient echo (GRE) sequence and a 32-channel phased array coil, permits diagnostic image quality, with potential application in patients unable to cooperate with breath-hold requirements. ...
متن کاملHighly-Accelerated Real-Time Cine MRI using compressed sensing and parallel imaging
Introduction Breath-hold cine MRI with balanced steady-steady free precession (b-SSFP) may yield non diagnostic image quality in patients with impaired breath-hold capacity and/or arrhythmias. In such patients, it may be necessary to perform real-time cine MRI. Currently, dynamic parallel imaging methods, such as TSENSE [1] and TGRAPPA [2], can be used to achieve only moderate acceleration rate...
متن کامل