Identification of resected root-end dentinal cracks: a comparative study of transillumination and dyes.

نویسندگان

  • Henry M Wright
  • Robert J Loushine
  • R Norman Weller
  • W Frank Kimbrough
  • Jennifer Waller
  • David H Pashley
چکیده

The dilemma of diagnosing and possibly treating dentinal cracks continues to present a challenge in endodontics. The purpose of this in vitro study was to compare the effectiveness of transillumination and dyes in identifying root-end dentinal cracks. Fifty maxillary central incisors were decoronated, and the canals were instrumented to an ISO size 50 at the working length. The apical 3 mm of the roots was resected, and cracks were artificially created in the apical dentin. Four independent examiners evaluated the root ends at x8 magnification with a surgical operating microscope using transillumination (group 1), sodium fluorescein dye (group 2), caries detect dye (group 3), methylene blue dye (group 4), and methylene blue plus transillumination (group 5). The examiners' ability to identify root ends correctly with and without cracks was analyzed by comparing the data with the predetermined standard (cracked and noncracked) using logistic regression analysis. All techniques used were shown to be more effective than random chance at diagnosing cracks. The areas under the curve of the different techniques were as follows: transillumination, 0.81 (95% confidence interval [CI], 0.69-0.93); sodium fluorescein, 0.72 (95% CI, 0.58-0.86); caries detector, 0.76 (95% CI, 0.63-0.89); methylene blue, 0.70 (95% CI, 0.55-0.84); and methylene blue plus transillumination, 0.82 (95% CI, 0.70-0.94). Thus, the crack assessment techniques that gave the best discrimination between cracked and noncracked specimens, regardless of rater, was methylene blue plus transillumination. This study emphasizes the usefulness of transillumination along with magnification in detecting dentinal cracks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Three Methods in the Diagnosis of Dentin Cracks Caused by Apical Resection

OBJECTIVE To compare three various methods in the diagnosis of dentinal cracks formed in the apical third after root resection. MATERIALS AND METHODS One hundred extracted human maxillary central incisors were selected. The root canals were prepared with step-back technique. Then 3mm from the apical end of all roots was cut perpendicular to the long axis of the tooth. The apical end of each r...

متن کامل

Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-...

متن کامل

Comparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum

Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first...

متن کامل

Evaluation of two different root-end cavity preparation techniques: A scanning electron microscope study

OBJECTIVE In this study, we aimed to evaluate and compare the dentinal walls of root-end cavities for the presence of cracks after cavity preparation using US retrotips and Er: YAG laser. MATERIALS AND METHODS Fifty single-rooted teeth were prepared by Protaper NiTi rotary system and obturated by lateral condensation. Three milimeters of root-end was resected. Twenty teeth were prepared with ...

متن کامل

In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 30 10  شماره 

صفحات  -

تاریخ انتشار 2004