Amplified flow-cytometric separation-free fluorescence immunoassays.
نویسندگان
چکیده
An equilibrium-type competitive-binding fluorescence immunoassay with high sensitivity and excellent precision is described that obviates separation of free from bound label. In the assay relatively large (10 microns diameter) antibody-coated non-fluorescent particles and very small (0.10 micron diameter) antigen-coated fluorescent latex particles are used. Soluble nonlabeled antigen competes with antigen on the microspheres for antibody binding sites on the larger spheres. After equilibrium is attained, the fluorescence distribution of 5000 of the large spheres is measured in a flow cytometer. The mean values for the fluorescence distribution obtained from samples containing known concentrations of soluble antigen are used to construct a standard displacement curve. In a prototype assay for the antigen horseradish peroxidase, a sensitivity of 10(-12) mol/L has been achieved. Undiluted serum can be assayed without loss of sensitivity. Preliminary experiments also indicate that double-antibody "sandwich"-type assays of very high sensitivity (10(-14) mol/L) are also possible when this dual-sphere concept is exploited.
منابع مشابه
Serum copper is decreased in premature newborns and increased in newborns with hemolytic jaundice.
with the individual protein testing capacity of the WB. The assay can be tailored to the requirements of screening or confirmatory testing as well as to the needs of specific vaccine studies. Vaccine trials could benefit greatly from a PBA that differentiates protected from infected individuals. Because large-scale vaccine studies are likely to be conducted in settings where conditions may not ...
متن کاملFlow Cytometry as a Tool for Quality Control of Fluorescent Conjugates Used in Immunoassays
The use of antibodies in immunodiagnostic kits generally implies the conjugation of these proteins with other molecules such as chromophores or fluorochromes. The development of more sensitive quality control procedures than spectrophotometry is essential to assure the use of better fluorescent conjugates since the fluorescent conjugates are critical reagents for a variety of immunodiagnostic k...
متن کاملFlow cytometric analysis of lymphoid enhancer-binding factor 1 in diagnosis of chronic lymphocytic leukemia/small lymphocytic lymphoma.
OBJECTIVES Nuclear overexpression of lymphoid enhancer-binding factor 1 (LEF1) assessed by immunohistochemistry has been shown to be highly associated with chronic lymphocytic leukemia/small lymphocytic lymphoma (CLL/SLL) among small B-cell lymphomas. The purpose of this study was to evaluate the utility of flow cytometric analysis of LEF1 in the diagnosis of CLL/SLL. METHODS Normal periphera...
متن کاملFluorescence Polarization Immunoassay of Mycotoxins: A Review
Immunoassays are routinely used in the screening of commodities and foods for fungal toxins (mycotoxins). Demands to increase speed and lower costs have lead to continued improvements in such assays. Because many reported mycotoxins are low molecular weight (below 1 kDa), immunoassays for their detection have generally been constructed in competitive heterogeneous formats. An exception is fluor...
متن کاملSimultaneous detection of antibodies to cytomegalovirus and herpes simplex virus by using flow cytometry and a microsphere-based fluorescence immunoassay.
A sensitive assay for the simultaneous detection of anti-cytomegalovirus and anti-herpes simplex virus antibodies was developed. Two different sizes of polystyrene microspheres were coated with purified viral antigens. Human antiviral antibodies were detected with a biotin-streptavidin amplification procedure with phycoerythrin as the fluorescent label. Microsphere-associated fluorescence was q...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 31 12 شماره
صفحات -
تاریخ انتشار 1985