Evaluating the different laser fragmentation patterns used in laser cataract surgeries in terms of effective phacoemulsification time and power

نویسندگان

  • Tukezban Huseynova
  • Mariko Mita
  • Christine Carole C Corpuz
  • Yuko Sotoyama
  • Minoru Tomita
چکیده

PURPOSE To evaluate the effects of the different fragmentation patterns for the lens nucleus in terms of the effective phacoemulsification time (EPT) and power. SETTING Shinagawa LASIK Center, Tokyo, Japan. DESIGN Comparison study. METHODS Seventy-one eyes of 71 patients had preoperative lens opacity grading based on the Emery-Little Classification (Grade 1 and Grade 2). Eyes underwent femtosecond laser-assisted cataract surgery (Catalys™ Precision Laser System), for capsulotomy and lens fragmentation. For the lens fragmentation, either the quadrants softened (Quadrant) or the quadrants complete (Complete) pattern was used. The mean EPT and phacoemulsification (phaco) power for each cutting pattern of Grades 1 and 2 cataracts were evaluated. RESULTS The mean EPT was 28.96 seconds in the Quadrant Group and 16.31 seconds in the Complete Group (P=0.006). The mean phaco power was 8.07% in the Quadrant Group and 4.77% in the Complete Group (P=0.0002). Comparing the Quadrant and Complete Groups of Grade 1 cataract showed no significant difference in EPT (P=0.16), but showed a significant difference in phaco power (P=0.033). Comparing the Quadrant and Complete patterns of Grade 2 cataract showed significant differences in both EPT (P=0.012) and phaco power (P=0.003). Using the Complete pattern showed a 44.7% reduction in EPT and a 40.9% reduction in phaco power when compared to the Quadrant Group. CONCLUSION Using the smaller fragmentation pattern in femtosecond laser cataract surgery, the phaco time and power were reduced significantly when compared to the procedure with the larger fragmentation pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of femtosecond laser fragmentation of the nucleus with different softening grid sizes on effective phaco time in cataract surgery.

PURPOSE To compare the effect of different fragmentation softening grids in femtosecond laser-assisted cataract surgery on effective phacoemulsification time (EPT). SETTING Ruhr University Eye Clinic, Bochum, Germany. DESIGN Prospective randomized clinical trial. METHODS The study evaluated the feasibility of using a femtosecond laser (Catalys Precision Laser System) to perform capsulotom...

متن کامل

Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery.

PURPOSE To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. METHODS Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addit...

متن کامل

Cataract Surgery Performed by High Frequency LDV Z8 Femtosecond Laser: Safety, Efficacy, and Its Physical Properties

BACKGROUND The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure. METHODS This prospective study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surge...

متن کامل

First experience with the new high-frequency femtosecond laser system (LDV Z8) for cataract surgery

BACKGROUND The purpose of this work is to report our experience using the new Z8 laser system for femtosecond laser-assisted cataract surgery (FLACS) and to provide a sample of the performance and safety results using this new technology. METHODS This prospective observational study was performed at the Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. Fourteen patients ...

متن کامل

Surgical efficiency in femtosecond laser cataract surgery compared with phacoemulsification cataract surgery: a case–control study

OBJECTIVES To investigate differences in surgical time, the distance the surgical instrument travelled and number of movements required to complete manual phacoemulsification cataract surgery versus femtosecond laser cataract surgery. DESIGN Non-randomised comparative case series. SETTING Single surgery site, Moorfields Eye Hospital, UK. PARTICIPANTS 40 cataract surgeries of 40 patients. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015