Integrated design of sewers and wastewater treatment plants.
نویسندگان
چکیده
Sewer system design must be integrated with wastewater treatment plant design when moving towards a more sustainable urban wastewater management. This integration allows an optimization of the design of both systems to achieve a better and more cost-effective wastewater management. Hitherto integrated process design has not been an option because the tools to predict in-sewer wastewater transformations have been inadequate. In this study the WATS model--being a new and validated tool for in-sewer microbial process simulations--is presented and its application for integrated sewer and treatment plant design is exemplified. A case study on a Malaysian catchment illustrates this integration. The effects of centralization of wastewater treatment and the subsequently longer transport distances are addressed. The layout of the intercepting sewer is optimized to meet the requirements of different treatment scenarios.
منابع مشابه
Upgrading Wastewater Treatment Plants Based on Reuse Demand, Technical and Environmental Policies (A Case Study)
Reclamation and reuse programs are an indispensable part of integrated water resource management, particularly in arid and semi arid regions. Yet, the feasibility of sustainable application not only is relied on design, operation and maintenance of wastewater treatment plants, but also could be influenced by the economical and environmental aspects of reuse demands. This study is aimed to illus...
متن کاملFuzzy Logic Control of Integrated Wastewater Systems
The increasing importance of environmental problems in the last decades, and the consequently stricter regulations adopted, require a holistic approach in control and operation of wastewater process, whose primary objective is to maintain a good state of the receiving waters. This paper reports the study focused on building a Fuzzy Logic Control for integrated wastewater systems. The control in...
متن کاملIntegrated modelling of biotransformation processes in sewer systems and wastewater treatment plants for optimising chemical dosing to sewer networks
Hydrogen sulfide, which is produced by sewer biofilms as a result of sulfate reduction under anaerobic conditions, has since long been identified as a major cause of corrosion and odour problems in a sewer system. Dosing of various types of chemicals to wastewater is widely used by the water industry as a control measure for these problems. Oxygen/air, nitrate salts, iron salts and magnesium hy...
متن کاملPolycyclic aromatic hydrocarbons in wastewater, WWTPs effluents and in the recipient waters of Beijing, China.
In this study, surface water samples from the Wenyu River and the North Canal, effluent from major wastewater treatment plants (WWTPs) in Beijing, and wastewater from open sewers that discharge directly into the river system were collected and analyzed for 16 priority USEPA polycyclic aromatic hydrocarbons (PAHs). Concentrations of these 16 PAHs ranged from 193 to 1790 ng/L in river surface wat...
متن کاملFactors Affecting the Quality of the Plant Influent and Its Suitability for Prefermentation and the Biological Nutrient Removal Process
To understand wastewater quality transformations in the sewer system, a full-scale study focused on the characteristics of the influent wastewater in a middle-sized wastewater-treatment plant receiving only municipal sewage. The objective was to identify conditions in which prefermentation prior to the biological nutrient removal (BNR) process would be useful. Prefermentation aims at increasing...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Water science and technology : a journal of the International Association on Water Pollution Research
دوره 46 9 شماره
صفحات -
تاریخ انتشار 2002