PEG-hirudin/iloprost coating of small diameter ePTFE grafts effectively prevents pseudointima and intimal hyperplasia development.
نویسندگان
چکیده
OBJECTIVES Small diameter PTFE grafts are prone to thrombosis and intimal hyperplasia development. Heparin graft coating has beneficial effects but also potential drawbacks. The purpose of this study was to evaluate the experimental efficacy of PEG-hirudin/iloprost coated small caliber PTFE grafts. METHODS Thirty-six femoro-popliteal ePTFE grafts (expanded polytetrafluoroethylene, diameter 4 mm) were inserted into 18 pigs. Grafts were randomised individually for each leg and grouped for 3 groups. Group I consisted of native ePTFE grafts, group II were grafts coated with a polylactide polymer (PLA) without drugs and group III grafts were coated with PLA containing a polyethylene glycol (PEG)-hirudin/iloprost combination. The follow-up period was 6 weeks. Patency rates were calculated and development of pseudointima inside the grafts was noted. Thickness of intimal hyperplasia at the distal anastomoses was measured using light microscopy. RESULTS Patency rates for group I were 6/9 (67%), for group II 9/10 (90%) and 12/12 (100%) for group III. In groups I and II there was a significant reduction of blood flow proximal to the graft at graft harvest, to 29+/-12 and 28+/-20 ml/min respectively (both p<0.01 versus preoperative value), whilst in group III blood flow, 99+/-21 ml/min, remained at the preoperative level. Subtotal stenosis due to development of pseudointima was noted in each of the native and PLA coated grafts but not in group III grafts. Intimal hyperplasia at the distal anastomosis was lowest in group III. CONCLUSIONS The PEG-hirudin/iloprost coating of ePTFE prostheses effectively reduced pseudointima and intimal hyperplasia development and led to superior graft patency.
منابع مشابه
Human Blood Vessel–Derived Endothelial Progenitors for Endothelialization of Small Diameter Vascular Prosthesis
BACKGROUND Coronary bypass graft failure as a result of acute thrombosis and intimal hyperplasia has been the major challenge in surgical procedures involving small-diameter vascular prosthesis. Coating synthetic grafts with patients' own endothelial cells has been suggested to improve the patency rate and overall success of bypass surgeries. METHODOLOGY/PRINCIPAL FINDINGS We isolated endothe...
متن کاملInhibition of neointima formation after experimental coronary artery stenting: a new biodegradable stent coating releasing hirudin and the prostacyclin analogue iloprost.
BACKGROUND To minimize acute stent thrombosis and development of restenosis, stents coated with biodegradable and nonbiodegradable polymers have been proposed to serve as sustained-release drug carriers. METHODS AND RESULTS In both a sheep and a pig model, we examined the vascular response to standard and high-pressure implantation of coronary Palmaz-Schatz stents coated with a 10-microm laye...
متن کاملAnastomotic Hemodynamics at the Distal End of Lower Extremity Bypass to Improve Patency
rosthetic arterial grafts constructed from expanded polytetrafluoroethylene (ePTFE) have been used for many years as an alternative to autologous vein grafts for lower extremity bypass. When anastomosed above the knee, their performance is similar to that of autologous vein for up to 2 years after operation, thereafter they are associated with a significantly higher failure rate.1 When anastomo...
متن کاملCitric acid-based elastomers provide a biocompatible interface for vascular grafts.
Prosthetic vascular bypass grafting is associated with poor long-term patency rates. Herein, we report on the mid-term performance of expanded polytetrafluoroethylene (ePTFE) vascular grafts modified with a citric acid-based biodegradable elastomer. Through a spin-shearing method, ePTFE grafts were modified by mechanically coating a layer of poly(1,8 octanediol citrate) (POC) onto the luminal n...
متن کاملModulating Expanded Polytetrafluoroethylene Vascular Graft Host Response via Citric Acid-Based Biodegradable Elastomers
Atherosclerotic vascular disease, in the form of coronary artery and peripheral vascular disease, remains the leading cause of mortality in the United States. For many patients, suitable vein autografts are not available. Synthetic grafts made from Dacron (polyethylene terephthalate) or expanded polytetrafluoroethylene (ePTFE) are mostly used in large-diameter (> 6 mm inner diameter) blood-vess...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
دوره 32 4 شماره
صفحات -
تاریخ انتشار 2006