Multi-frequency EIT system with radially symmetric architecture: KHU Mark1.

نویسندگان

  • Tong In Oh
  • Eung Je Woo
  • David Holder
چکیده

We describe the development of a multi-frequency electrical impedance tomography (EIT) system (KHU Mark1) with a single balanced current source and multiple voltmeters. It was primarily designed for imaging brain function with a flexible strategy for addressing electrodes and a frequency range from 10 Hz-500 kHz. The maximal number of voltmeters is 64, and all of them can simultaneously acquire and demodulate voltage signals. Each voltmeter measures a differential voltage between a pair of electrodes. All voltmeters are configured in a radially symmetric architecture in order to optimize the routing of wires and minimize cross-talk. We adopted several techniques from existing EIT systems including digital waveform generation, a Howland current generator with a generalized impedance converter (GIC), digital phase-sensitive demodulation and tri-axial cables. New features of the KHU Mark1 system include multiple GIC circuits to maximize the output impedance of the current source at multiple frequencies. The voltmeter employs contact impedance measurements, data overflow detection, spike noise rejection, automatic gain control and programmable data averaging. The KHU Mark1 system measures both in-phase and quadrature components of trans-impedances. By using a script file describing an operating mode, the system setup can be easily changed. The performance of the developed multi-frequency EIT system was evaluated in terms of a common-mode rejection ratio, signal-to-noise ratio, linearity error and reciprocity error. Time-difference and frequency-difference images of a saline phantom with a banana object are presented showing a frequency-dependent complex conductivity of the banana. Future design of a more innovative system is suggested including miniaturization and wireless techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Weighted frequency-difference EIT measurement of hemisphere phantom

We have proposed a new frequency difference method using a weighted voltage difference (WFD-EIT) between two frequencies [1, 2]. Previous studies demonstrated its feasibility through numerical experiments and two-dimensional phantom experiments. In this study, we validate the WFD-EIT algorithm on a three-dimensional hemisphere phantom using a multi-frequency EIT system KHU Mark1. We built the h...

متن کامل

Calibration methods for a multi-channel multi-frequency EIT system.

Multi-channel multi-frequency electrical impedance tomography (EIT) systems require a careful calibration to minimize systematic errors. We describe novel calibration methods for the recently developed KHU Mark1 EIT system. Current source calibration includes maximization of output resistance and minimization of output capacitance using multiple generalized impedance converters. Phase and gain ...

متن کامل

Validation of a multi-frequency electrical impedance tomography (mfEIT) system KHU Mark1: impedance spectroscopy and time-difference imaging.

Validation and interpretation of reconstructed images using a multi-frequency electrical impedance tomography (mfEIT) requires a conductivity phantom including imaging objects with known complex conductivity (sigma + iomegaepsilon) spectra. We describe imaging experiments using the recently developed mfEIT system called the KHU Mark1 with the frequency range of 10 Hz to 500 kHz. Using a bio-imp...

متن کامل

Electrical Impedance Tomography System for detecting fast physiological signal: KHU Mark2.5

Electrical impedance Tomography (EIT) can produce real-time images of conductivity variations associated with respiratory and cardiac cycles. We report the development of a new multi-frequency EIT system called the KHU Mark2.5. It has new features such as flexible electrode configurations to accommodate application-specific requirements, multiple independent current sources and voltmeters for f...

متن کامل

Electrical impedance imaging system using FPGAs for flexibility and interoperability

BACKGROUND Modern EIT systems require simultaneously operating multiple functions for flexibility, interoperability, and clinical applicability. To implement versatile functions, expandable design and implementation tools are needed. On the other hand, it is necessary to develop an ASIC-based EIT system to maximize its performance. Since the ASIC design is expensive and unchangeable, we can use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2007