Implementation of low-energy surface-induced dissociation (eV SID) and high-energy collision-induced dissociation (keV CID) in a linear sector-TOF hybrid tandem mass spectrometer
نویسندگان
چکیده
In the work reported here, an in-line sector-TOF (time-of-flight) tandem mass spectrometer with a coaxial detector was developed. An advantage of the present design is that the instrument implements both high-energy collision-induced dissociation (keV CID) and low-energy surface-induced dissociation (eV SID) with no hardware manipulations required to switch between the two activation methods. Surface characterization by secondary-ion mass spectrometry is also possible with this design. Gas phase collision-induced dissociation in this sector-TOF requires ion gating of the continuous ion beam and an ion buncher to bring the ions into spatial focus at the focal-point “source” of the offset parabolic field reflectron. The offset parabolic field reflectron provides good resolution over virtually the entire product ion mass range, with no need to step the reflector voltages. For surface-induced dissociation experiments, accomplished with a surface placed after the last reflectron electrode, the electrodes that comprise the CID reflectron are used for deceleration and acceleration of the ion beam before and after it collides with the surface, respectively. The results obtained show successful implementation of keV CID and eV SID in a JEOL HX110A/TOF mass spectrometer. Product ion mass accuracy is better than 0.4 u for keV CID and 0.1 u for eV SID. Typical resolutions achieved are 8000–12,000 (for selected ions), 1000 (for keV CID fragments), and 300–400 (for eV SID fragments). This difference in the CID and SID resolution is partially the result of the different total flight times in CID and SID experiments. On the basis of a direct comparison of keV CID and eV SID of protonated leucine enkephalin, SID experiments have a lower detection limit than CID experiments by at least an order of magnitude. (Int J Mass Spectrom 212 (2001) 535–551) © 2001 Elsevier Science B.V.
منابع مشابه
Protein identification via surface-induced dissociation in an FT-ICR mass spectrometer and a patchwork sequencing approach.
Surface-induced dissociation (SID) and collision-induced dissociation (CID) are ion activation techniques based on energetic collisions with a surface or gas molecule, respectively. One noticeable difference between CID and SID is that SID does not require a collision gas for ion activation and is, therefore, directly compatible with the high vacuum requirement of Fourier transform ion cyclotro...
متن کاملDetailed Structural Analysis of Lipids Directly on Tissue Specimens Using a MALDI-SpiralTOF-Reflectron TOF Mass Spectrometer
Direct tissue analysis using a novel tandem time-of-flight (TOF-TOF) mass spectrometer is described. This system consists of a matrix-assisted laser desorption/ionization ion source, a spiral ion trajectory TOF mass spectrometer "SpiralTOF (STOF)", a collision cell, and an offset parabolic reflectron (RTOF). The features of this system are high precursor ion selectivity due to a 17-m flight pat...
متن کاملTandem fourier transform mass spectrometry studies of surface-induced dissociation of benzene monomer and dimer ions on a self-assembled fluorinated alkanethiolate monolayer surface.
A new instrument configuration based on a Finnigan FTMS-2000 platform has been applied to the study of surface-induced dissociation (SID) in this research. Benzene monomer ions C(6)H(6)(+) and dimer ions (C(6)H(6))(2)(+) were impacted on a fluorinated self-assembled monolayer surface at collision energies ranging from 1 to 70 eV. Benzene cations were chosen for this study because the fragmentat...
متن کاملIon activation methods for tandem mass spectrometry.
This tutorial presents the most common ion activation techniques employed in tandem mass spectrometry. In-source fragmentation and metastable ion decompositions, as well as the general theory of unimolecular dissociations of ions, are initially discussed. This is followed by tandem mass spectrometry, which implies that the activation of ions is distinct from the ionization step, and that the pr...
متن کاملSurface-induced dissociation of ions produced by matrix-assisted laser desorption/ionization in a fourier transform ion cyclotron resonance mass spectrometer.
Intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source was constructed and interfaced with a 6-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially configured for surface-induced dissociation (SID) studies. First MALDI-SID results in FT-ICR are presented, demonstrating unique advantages of SID over conventional FT-ICR MS ion activation te...