Transpulmonary pressure and gas exchange during decremental PEEP titration in pulmonary ARDS patients.

نویسندگان

  • Pablo O Rodriguez
  • Ignacio Bonelli
  • Mariano Setten
  • Shiry Attie
  • Matias Madorno
  • Luis P Maskin
  • Ricardo Valentini
چکیده

BACKGROUND Selection of the PEEP associated with the best compliance of the respiratory system during decremental PEEP titration can be used for the treatment of patients suffering from ARDS. We describe changes in transpulmonary pressure (Ptp) and gas exchange during a decremental PEEP titration maneuver in subjects with pulmonary ARDS. METHODS Eleven subjects with early ARDS were included. After a recruitment maneuver they were ventilated in volume-controlled ventilation and PEEP was decreased from 30 to 0 cm H2O by steps of 3 cm H2O. Static airway pressure (Paw), esophageal pressure (Pes), Ptp (Paw - Pes), the ratio of dead space to tidal volume (VD/VT), and PaO2 were recorded at each step. RESULTS A linear correlation was found between Paw and Ptp. Expiratory Ptp became negative in all subjects when PEEP decreased below 8.9 ± 5.2 cm H2O. VD/VT was 0.67 ± 0.06 with 30 cm H2O of PEEP, and decreased 15.4 ± 8.5% during the maneuver, when PEEP and expiratory Ptp were 10.6 ± 4.1 cm H2O and 1.2 ± 2.8 cm H2O, respectively. VD/VT was significantly higher during ventilation at high (> 18 cm H2O), compared to low, inspiratory Ptp values (P < .001). PaO2 decreased when expiratory Ptp became negative (P < .001). CONCLUSIONS During decremental PEEP titration we sequentially observed high inspiratory Ptp that stressed lung tissue and increased VD/VT, and negative Ptp, indicating high risk of alveolar collapse, explaining worse oxygenation. PEEP selection based on Ptp and VD/VT in ARDS may help to avoid these situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dead space fraction changes during PEEP titration following lung recruitment in patients with ARDS.

BACKGROUND Elevated dead space fraction (the ratio of dead space to tidal volume [V(D)/V(T)]) is a feature of ARDS. PEEP can partially reverse atelectasis, prevent alveoli recollapse, and improve lung compliance and gas exchange in patients with ARDS. However, whether V(D)/V(T) variables have a close relationship with PEEP and collapse alveolar recruitment remains under recognized. Meanwhile, f...

متن کامل

Efficacy of positive end-expiratory pressure titration after the alveolar recruitment manoeuvre in patients with acute respiratory distress syndrome

INTRODUCTION In acute respiratory distress syndrome (ARDS), adequate positive end-expiratory pressure (PEEP) may decrease ventilator-induced lung injury by minimising overinflation and cyclic recruitment-derecruitment of the lung. We evaluated whether setting the PEEP using decremental PEEP titration after an alveolar recruitment manoeuvre (ARM) affects the clinical outcome in patients with ARD...

متن کامل

Positive End-expiratory Pressure Titration after Alveolar Recruitment Directed by Electrical Impedance Tomography

BACKGROUND Electrical impedance tomography (EIT) is a real-time bedside monitoring tool, which can reflect dynamic regional lung ventilation. The aim of the present study was to monitor regional gas distribution in patients with acute respiratory distress syndrome (ARDS) during positive-end-expiratory pressure (PEEP) titration using EIT. METHODS Eighteen ARDS patients under mechanical ventila...

متن کامل

Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome

INTRODUCTION To investigate haemodynamic and respiratory changes during lung recruitment and decremental positive end-expiratory pressure (PEEP) titration for open lung ventilation in patients with acute respiratory distress syndrome (ARDS) a prospective, clinical trial was performed involving 12 adult patients with ARDS treated in the surgical intensive care unit in a university hospital. ME...

متن کامل

Physiologic effects of alveolar recruitment and inspiratory pauses during moderately-high-frequency ventilation delivered by a conventional ventilator in a severe lung injury model

BACKGROUND AND AIMS To investigate whether performing alveolar recruitment or adding inspiratory pauses could promote physiologic benefits (VT) during moderately-high-frequency positive pressure ventilation (MHFPPV) delivered by a conventional ventilator in a porcine model of severe acute respiratory distress syndrome (ARDS). METHODS Prospective experimental laboratory study with eight pigs. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 5  شماره 

صفحات  -

تاریخ انتشار 2013