Patch testing with 2.0% (0.60 mg/cm 2) formaldehyde instead of 1.0% (0.30 mg/cm 2) detects significantly more contact allergy.
نویسندگان
چکیده
BACKGROUND The currently used patch test concentration for formaldehyde is 1.0% (wt/vol) in water. However, clinical experience and previous studies suggest that 1.0% might be insufficient for detecting an optimized number of clinically relevant cases of contact allergy to formaldehyde. OBJECTIVES To validate earlier patch test results for comparison of 1% (wt/vol) and 2% (wt/vol) formaldehyde in water, and to investigate co-reactivity with quaternium-15. MATERIALS AND METHODS In 12 dermatology clinics, 3591 patients were routinely patch tested simultaneously with 2.0% (wt/vol) (0.60 mg/cm(2)) and 1.0% (wt/vol) (0.30 mg/cm(2)) formaldehyde. Micropipettes were used for delivering the exact dosage of the allergen. RESULTS Significantly more patients reacted to 2.0% formaldehyde than to 1.0% (3.4% versus 1.8%, p < 0.001). Overall, there were no sex differences between those reacting positively to 2.0% and 1.0%. Of 25 quaternium-15-positive patients, 4 (0.1%) reacted positively without reacting to formaldehyde. CONCLUSION On the basis of the results of this multicentre study, as well as of previous studies, it can be suggested that 2.0% (wt/vol) in water formaldehyde should be used in routine patch testing in the baseline series.
منابع مشابه
Patch testing with formaldehyde 2.0% in parallel with 1.0% by the Swedish contact dermatitis research group.
In a multicentre study consecutively patch-tested dermatitis patients were tested simultaneously with 1.0% and 2.0% (w/v) formaldehyde in aqua applied with a micropipette (15 µl) to the filter paper disc in Finn Chambers (0.30 mg/cm(2) and 0.60 mg/cm(2), respectively). A total of 2,122 dermatitis patients were patch-tested. In all, 77 (3.6%) patients reacted positively to formaldehyde; 37 react...
متن کاملRecommendation to include formaldehyde 2.0% aqua in the European baseline patch test series.
BACKGROUND The currently used patch test concentration of formaldehyde (1.0% aqua; 0.30 mg/cm(2)) has been shown to fail to detect ~ 50% of contact allergies to formaldehyde. OBJECTIVES To justify the inclusion of formaldehyde 2.0% aqua (0.60 mg/cm(2)) in the European baseline patch test series. METHODS A survey of the reported frequencies of contact allergy to formaldehyde found with forma...
متن کاملRecommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.
BACKGROUND The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. OBJECTIVE To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, c...
متن کاملRecommendation to increase the test concentration of methylchloroisothiazolinone/methylisothiazolinone in the European baseline patch test series - on behalf of the European Society of Contact Dermatitis and the European Environmental and Contact Dermatitis Research Group.
BACKGROUND Methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) in aqua is present in the European baseline patch test series at 100 ppm, whereas 200 ppm has been used in Sweden since 1986, in Spain in the late 1980s, and, in recent years, also in the United Kingdom and Ireland. OBJECTIVES With regard to MCI/MI, to investigate the data on contact allergy rates in dermatitis patients, ...
متن کاملFormaldehyde-releasers: relationship to formaldehyde contact allergy. Contact allergy to formaldehyde and inventory of formaldehyde-releasers.
This is one of series of review articles on formaldehyde and formaldehyde-releasers (others: formaldehyde in cosmetics, in clothes and in metalworking fluids and miscellaneous). Thirty-five chemicals were identified as being formaldehyde-releasers. Although a further seven are listed in the literature as formaldehyde-releasers, data are inadequate to consider them as such beyond doubt. Several ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Contact dermatitis
دوره 68 1 شماره
صفحات -
تاریخ انتشار 2013