Exploring Frequency Domain OCT Systems

نویسنده

  • John Grasel
چکیده

Frequency domain optical coherence tomography allows for in-vivo nondestructive imaging at speeds two orders of magnitude faster than time domain methods while increasing the signal to noise ratio. These benefits are the result of acquiring information on all scatterers in a depth scan all the time. We explore methods of maintaining depth resolution through dispersion compensation and lateral resolution and signal to noise ratio through slab-based OCT and Bessel beams, and we examine methods of resolving the complex conjugate ambiguity. We investigate ISAM and its ability to dynamically refocus data in software, and look at ways of maintaining the phase stability necessary for motion sensitivity. We calculate what specifications a hypothetical instrument would have compared to our current designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forward-viewing resonant fiber-optic scanning endoscope of appropriate scanning speed for 3D OCT imaging

A forward-viewing resonant fiber-optic endoscope of a scanning speed appropriate for a high-speed Fourier-domain optical coherence tomography (FD-OCT) system was developed to enable real-time, three-dimensional endoscopic OCT imaging. A new method was explored to conveniently tune the scanning frequency of a resonant fiber-optic scanner, by properly selecting the fiber-optic cantilever length, ...

متن کامل

Comparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements

BACKGROUND The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS Fifty...

متن کامل

OCT versus IVUS: accuracy versus clinical utility.

The technology of optical coherence tomography (OCT) has evolved from time-domain to frequencydomain imaging. Time-domain OCT is most often performed using proximal balloon occlusion; as such, dimensions are smaller than measured using intravascular ultrasound (IVUS), presumably due to diminished perfusion pressure. Conversely, frequency-domain OCT does not require proximal balloon occlusion, t...

متن کامل

Single-Carrier Frequency-Domain Equalization for Orthogonal STBC over Frequency-Selective MIMO-PLC channels

In this paper we propose a new space diversity scheme for broadband PLC systems using orthogonal space-time block coding (OSTBC) transmission combined with single-carrier frequency-domain equalization (SC-FDE). To apply this diversity technique to PLC channels, we first propose a new technique for combining SC-FDE with OSTBCs applicable to all dispersive multipath channels impaired by impulsive...

متن کامل

Extended coherence length Fourier domain mode locked lasers at 1310 nm.

Fourier domain mode locked (FDML) lasers are excellent tunable laser sources for frequency domain optical coherence tomography (FD-OCT) systems due to their combination of high sweep rates, large tuning ranges, and high output powers. However, conventional FDML lasers provide coherence lengths of only 4-10 mm, limiting their use in demanding applications such as intravascular OCT where coherenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011