Development and validation of a spontaneous smile assay.
نویسندگان
چکیده
IMPORTANCE Smiling can be a voluntary or involuntary movement. Facial reanimation procedures differ in their ability to restore a spontaneous smile, and an assay designed to evoke and evaluate a spontaneous smile is not available. OBJECTIVE To develop and validate an assay to assess the spontaneous smile of patients with facial paralysis. DESIGN, SETTING, AND PARTICIPANTS This was an exploratory cohort study. A series of short video clips were administered to laypersons via an online survey service from January 1, 2014, to March 31, 2014. Respondents rated how funny each video was on a visual analog scale from 0 to 100. The 4 funniest videos were selected to generate a 1½-minute spontaneous smile assay. The assay was then administered from July 1, 2014, to December 31, 2014, to 2 different study groups: the first was composed of 100 healthy individuals (control group) and the second was composed of 30 patients with facial paralysis. We analyzed the capability of this assay to provoke at least 1 spontaneous smile and calculated smile excursion in both groups. Statistical analysis was performed using analysis of variance. INTERVENTION Spontaneous smile assay administered to both healthy and diseased groups. MAIN OUTCOMES AND MEASURES Ability of the assay to elicit smiles, as defined by an oral commissure excursion greater than 3 mm, as well as difference in commissure excursion. RESULTS Ninety-five (95.0%) participants in the control group and 29 (96.7%) patients with facial paralysis experienced at least 1 oral commissure excursion that appeared to be a spontaneous smile while viewing the assay. Mean oral commissure excursion with spontaneous smile was 9.08 mm (95% CI, 2.77-15.39) in controls, 6.72 mm (95% CI, 3.13-10.31) on the healthy side in patients with flaccid facial paralysis (P=.004 vs controls), and 9.64 mm (95% CI, 3.52-15.76) on the healthy side in patients with nonflaccid facial paralysis (P=.74). Among patients with flaccid facial paralysis, a statistically significant difference was found between smile excursion of the affected and the unaffected sides (P = .03). There was no statistically significant difference in the measurement between sides for the control group (P = .67). CONCLUSIONS AND RELEVANCE Although humor is a challenging construct to universalize, our assay was able to elicit a smile in almost all individuals in the group with facial paralysis and the control group. The spontaneous smile assay will facilitate future research on the ability of facial reanimation procedures and other interventions to restore a spontaneous smile. LEVEL OF EVIDENCE NA.
منابع مشابه
Role of smile correction in mineral detection on hyperion data
This work aims to extract the mineralogical constituents of the Lahroud Hyperion scene situated in the NW of Iran. Like the other push-broom sensors, Hyperion images suffer from spectral distortions, namely the smile effect. The corresponding spectral curvature is defined as an across-track wavelength shift from the nominal central wavelength, and alters the pixel spectra. The common “column me...
متن کاملOrigins of smile and laughter: a preliminary study.
To present fundamental data, spontaneous smiles and spontaneous laughs (smiles accompanied by vocal sounds) were cross-sectionally observed in 10 newborn infants and longitudinally observed in six infants. Unilateral spontaneous smiles were more common than bilateral smiles in neonates, but by 2 months almost all spontaneous smiles were bilateral. All spontaneous laughs were bilateral. "Spontan...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL
An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA facial plastic surgery
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2015