Pneumatic reduction of intussusception using equipment readily available in the hospital.

نویسندگان

  • M A Zulfiqar
  • M Noryati
  • A H Hamzaini
  • C R Thambidorai
چکیده

The purpose of this study was to determine the effectiveness of pneumatic reduction of intussusception using equipment readily available in the hospital. Twenty-two children aged between four months and four years had pneumatic reduction of intussusception. The device used was assembled using (i) a hand-held pump attached to a pressure gauge, and (ii) a 3-way Foley's balloon catheter. There was a 73% success rate and there were no complications. The device used was effective and safe for the pneumatic reduction of intussusception.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-Guided Hydrostatic Reduction of Childhood Intussusceptions Using Water Enema

Conventional hydrostatic barium reduction or pneumatic reduction of intussusception is associated with considerable ionizing radiation. The aim of this study was to evaluate ultrasound-guided hydrostatic reduction for childhood intussusception using water enema. A total of 76 children who diagnosed as having intussusception were referred to Doctor Sheikh Children Hospital in Mashhad (northeast ...

متن کامل

Pneumatic reduction of intussusception: factors affecting outcome in Thailand

Background: Pneumatic reduction has become a therapeutic method for intussusception instead of surgery. It is more successful than barium reduction, but it depends on how much the operator is familiar with the method and equipment. Objective: Determine success rate and recurrent rate of intussusception and factors affecting outcome of pneumatic reduction in Thailand. Materials and methods: Fift...

متن کامل

Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction

PURPOSE Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success...

متن کامل

Pneumatic reduction of intussusception in children at the Komfo Anokye Hospital, Kumasi, Ghana.

OBJECTIVE To evaluate the role of pneumatic reduction in the management of intussusception in children in the setting of a sub-Saharan African nation. DESIGN Prospective case series. SETTING Tertiary care teaching hospital in Kumasi, Ghana. SUBJECTS Forty four children, aged 4 months to 13 years, 28 boys and 16 girls, were admitted with a clinical diagnosis of intussusception and confirme...

متن کامل

Treatment of pediatric intussusception by pneumatic reduction under ultrasound guidance: first case of King Chulalongkorn Memorial Hospital

Pneumatic or air enema under ultrasound guidance is the most recently developed technique for non-surgical treatment of pediatric intussusception with obvious advantage of radiation-free. The first case of King Chulalongkorn Memorial Hospital who was successfully treated for uncomplicated ileocolic intussusception by this technique is hereby reported. The clinical history, methods for diagnosis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 61 2  شماره 

صفحات  -

تاریخ انتشار 2006