Accuracy of funduscopy to identify true edema versus pseudoedema of the optic disc.

نویسندگان

  • Arturo Carta
  • Stefania Favilla
  • Marco Prato
  • Stefania Bianchi-Marzoli
  • Alfredo A Sadun
  • Paolo Mora
چکیده

PURPOSE Differential diagnosis between acute optic disc edema (ODE) and optic disc pseudoedema (PODE) may be a clinical challenge even for well-trained ophthalmologists. Funduscopy remains the first-line investigation. The aim of this study was to assess the accuracy, sensitivity, and specificity of funduscopy in differentiating ODE from PODE. METHODS This was an observational, cross-sectional, two-center study of subjects referred for presumed acute ODE. During funduscopy, each observer completed a form concerning the presence/absence of the 10 conventional signs of ODE. Seventy-four patients with ODE and 48 subjects with PODE were included in the analysis. Accuracy, sensitivity, and specificity from all possible combinations of signs were calculated by support vector machine (SVM) analysis. RESULTS As a single sign, the swelling of the peripapillary retinal nerve fiber layer had the highest accuracy (0.92; 95% confidence interval [CI], 0.82-0.97). Little variation was observed when more than fours signs were present. The best four-sign combinations were SWELLING, HEMORRHAGES, papilla ELEVATION, and CONGESTION of peripapillary vessels (accuracy, 0.93; 95% CI, 0.83-0.98; sensitivity, 0.95; specificity, 0.89). The presence of retinal or choroidal folds appeared to be a pathognomonic sign of true ODE (100% sensitivity) but had a low rate of presentation (23%). CONCLUSIONS The presence of at least four ophthalmoscopic signs (with the sign "swelling" included) gives the highest accuracy. Furthermore, peripapillary retinal folds seem to be related exclusively to ODE because they were never observed in our PODE group. These data may be useful for clinicians when evaluating patients referred for presumed optic disc edema in the acute phase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing

Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...

متن کامل

Evaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing

Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...

متن کامل

Peripapillary Intrachoroidal Cavitation and Optic Pit in a Case of High Myopia and Glaucoma

Purpose: To report a case of peripapillary intrachoroidal cavitation (choroidal schisis) and optic pit in a case of high myopia and open-angle glaucoma. Case report: A 30-year-old high myopic man was referred to our clinic for presumed peripapillary choroidal tumors. In funduscopy, there were two yellow-orange and slightly elevated peripapillary lesions in both eyes with indistinct margins. A s...

متن کامل

Automatic Optic Disc Center and Boundary Detection in Color Fundus Images

Accurately detection of retinal landmarks, like optic disc, is an important step in the computer aided diagnosis frameworks. This paper presents an efficient method for automatic detection of the optic disc’s center and estimating its boundary. The center and initial diameter of optic disc are estimated by employing an ANN classifier. The ANN classifier employs visual features of vessels and th...

متن کامل

Assessment of cup-to-disc ratio with slit-lamp funduscopy, Heidelberg Retina Tomography II, and stereoscopic photos.

PURPOSE To compare optic disc measurements achieved by slit-lamp funduscopy, Heidelberg Retina Tomography II (HRT II), and stereoscopic optic nerve photos (SONP) in glaucomatous, ocular hypertensive, and normal eyes. METHODS A total of 176 eyes (glaucomatous [n=87], ocular hypertensive [n=40], and normal eyes [n=49]) of 90 participants were studied. Each participant underwent a full ophthalmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2012