Robust adiabatic T2 preparation for fast whole brain spiral myelin water imaging at 3 Tesla

نویسندگان

  • Thanh D. Nguyen
  • Kofi Deh
  • Ashish Raj
  • Martin Prince
  • Yi Wang
  • Susan A. Gauthier
چکیده

Fig.5. Examples of T2W anatomical images and corresponding MWF maps from an RRMS patient (arrows indicate lesions). Fig.4. Examples of spiral T2W source images and MWF maps obtained with COMP T2prep showing severe artifacts (arrows). BIR-4 T2prep provides artifact free source images and MWF maps with exquisite details in the cortical areas. Robust adiabatic T2 preparation for fast whole brain spiral myelin water imaging at 3 Tesla Thanh D. Nguyen, Kofi Deh, Ashish Raj, Martin Prince, Yi Wang, and Susan A. Gauthier Radiology, Weill Cornell Medical College, New York, NY, United States, Neurology and Neuroscience, Weill Cornell Medical College, New York, NY, United States

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adiabatic T2-preparation modules optimized for robustness toward cardiac motion and flow - a comparison with existing techniques at 3 Tesla

Background T2-imaging of the heart at 3 Tesla demands T2-preparations not only insensitive to B0 and B1, but also toward cardiac motion and flow in order to avoid flow artifacts and concomitant myocardial contamination and to preserve endocardial border definition. While more refocusing pulses per T2-prep duration improve robustness, they also increase SAR. We chose four BIREF-1 refocusing puls...

متن کامل

Untangling the R2* contrast in multiple sclerosis: A combined MRI-histology study at 7.0 Tesla

T2*-weighted multi-echo gradient-echo magnetic resonance imaging and its reciprocal R2* are used in brain imaging due to their sensitivity to iron content. In patients with multiple sclerosis who display pathological alterations in iron and myelin contents, the use of R2* may offer a unique way to untangle mechanisms of disease. Coronal slices from 8 brains of deceased multiple sclerosis patien...

متن کامل

Measuring longitudinal myelin water fraction in new multiple sclerosis lesions

OBJECTIVES Investigating the potential of myelin repair strategies in multiple sclerosis (MS) requires an understanding of myelin dynamics during lesion evolution. The objective of this study is to longitudinally measure myelin water fraction (MWF), an MRI biomarker of myelin, in new MS lesions and to identify factors that influence their subsequent myelin content. METHODS Twenty-three MS pat...

متن کامل

Multi-Compartment T2 Relaxometry Using a Spatially Constrained Multi-Gaussian Model

The brain's myelin content can be mapped by T2-relaxometry, which resolves multiple differentially relaxing T2 pools from multi-echo MRI. Unfortunately, the conventional fitting procedure is a hard and numerically ill-posed problem. Consequently, the T2 distributions and myelin maps become very sensitive to noise and are frequently difficult to interpret diagnostically. Although regularization ...

متن کامل

Magnetization transfer from inhomogeneously broadened lines (ihMT): Experimental optimization of saturation parameters for human brain imaging at 1.5 Tesla.

PURPOSE Recently a new MR endogenous contrast mechanism was reported. It allows specifically imaging the magnetization transfer (MT) effect arising from inhomogeneously broadened components of the NMR spectrum, and was hence dubbed ihMT. Such unique NMR lineshape properties are presumably occurring in myelin because of its specifically ordered, multilayered sheath structure. Here, optimization ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013