Direct comparison of in-vivo and post-mortem spin-echo based diffusion tensor imaging in the porcine heart

نویسندگان

  • Christian T Stoeck
  • Constantin von Deuster
  • Nikola Cesarovic
  • Martin Genet
  • Maximilian Y Emmert
  • Sebastian Kozerke
چکیده

Background Spin-echo based cardiac diffusion tensor imaging (DTI) is highly sensitive to myocardial strain [1]. Imaging during systolic contraction requires precise planning of the sequence timing [2]. Second order motion compensated diffusion encoding has recently been proposed for small animal imaging [3] to reduce the impact of myocardial strain on the diffusion tensor. It is the objective of the present work to compare second order motion compensated spin-echo DTI of the in-vivo and post-mortem porcine heart on a clinical MR system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diffusion imaging of whole, post-mortem human brains on a clinical MRI scanner

Diffusion imaging of post mortem brains has great potential both as a reference for brain specimens that undergo sectioning, and as a link between in vivo diffusion studies and "gold standard" histology/dissection. While there is a relatively mature literature on post mortem diffusion imaging of animals, human brains have proven more challenging due to their incompatibility with high-performanc...

متن کامل

Second order motion compensated spin-echo diffusion tensor imaging of the human heart

PURPOSE Myocardial microstructure has been challenging to probe in vivo. Spin echo-based diffusion-weighted sequences allow for single-shot acquisitions but are highly sensitive to cardiac motion. In this study, the use of second-order motion-compensated diffusion encoding was compared with first-order motion-compensated diffusion-weighted imaging during systolic contraction of the heart. MET...

متن کامل

Second order motion compensated spin echo cardiac diffusion tensor imaging on clinical MR systems

Background Recently second order motion compensated spin echo (SE) sequences in conjunction with high performance gradient systems have been proposed for diffusion weighted (DWI) [1] and diffusion tensor imaging (DTI) [2,3] of the human in vivo heart. The method allows for free breathing acquisition without requiring dedicated patient feedback systems or other provisions [4], facilitating the t...

متن کامل

Diffusion tractography of post-mortem human brains: Optimization and comparison of spin echo and steady-state free precession techniques

Diffusion imaging of post-mortem brains could provide valuable data for validation of diffusion tractography of white matter pathways. Long scans (e.g., overnight) may also enable high-resolution diffusion images for visualization of fine structures. However, alterations to post-mortem tissue (T2 and diffusion coefficient) present significant challenges to diffusion imaging with conventional di...

متن کامل

In Vivo Diffusion Tensor Imaging of the Rat Spinal Cord – Pilot Study

In vivo diffusion tensor imaging (DTI) of rat thoracic spinal cord was performed on five healthy rats. Axial diffusion images were obtained using a standard spin echo diffusion weighted sequence. The fractional anisotropy (FA), longitudinal (LD) and transverse (TD) diffusivities and the mean diffusivity were estimated. Differences in these parameters between white and grey matter were in accord...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015