Noise identification and sampling frequency determination for precise Pb isotopic measurements by quadrupole-based Inductively Coupled Plasma Mass Spectrometry
نویسنده
چکیده
Analytical precision of the isotope ratios measured by quadrupole-based ICP-MS is drastically controlled by the lowfrequency noises which originate from nebulisation and vaporisation processes, and from sample introduction systems. The undesirable influence of these latter can be however reduced by choosing efficiently the operating parameters. In the present study, the choice of the stabilisation time necessary in peak jump mode, and the one of the number of sweeps are discussed in the light of noise power spectra obtained with various speeds of the peristaltic pump used as sample introduction system. Obviously, the settings proposed are probably efficient only on our own ICP-MS, but they can be determined without any difficulty on any other equipment, only by following the methodology detailed here. With such guidelines, experimental within-run RSD % were observed following closely those predicted by the counting statistics (∼ 110 %). The isotopic measurements of natural samples (overbank sediments, airborne particulate matter, lichens and rainwater) exhibited fair accuracy and good reproducibility, making highly convenient the use of the ICP-MS, at least in an environmental purpose.
منابع مشابه
Determination of sulfur in fossil fuels by isotope dilution electrothermal vaporization inductively coupled plasma mass spectrometry
The determination of S by solution nebulization quadrupole inductively coupled plasma mass spectrometry (ICP-MS) is dif®cult because of interferences from oxygen dimer ions. The large O2 z ion current from the solvent water is a serious interference at S, the most abundant of the four isotopes, and precludes its measurement. The isotopic composition of S varies in nature as a consequence of nat...
متن کاملDetermination of Cu, Zn, Cd and Pb in ®sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry
Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USSETV-ID-ICP-MS) has been applied to the determination of Cu, Zn, Cd and Pb in several ®sh reference samples. NH4NO3 was added to the sample solution to work as a modi®er. Since the sensitivity of the elements studied in ®sh slurry and aqueous solution was quite different, isot...
متن کاملICP-MS determination of lead isotope ratios in legal and counterfeit cigarette tobacco samples.
A method for the determination of Pb isotope ratios (IR) in cigarette tobacco by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) has been developed and applied to tobacco samples from genuine and counterfeit cigarettes obtained in the USA. The IR ²⁰⁷Pb/²⁰⁶Pb, (208)Pb/²⁰⁶Pb, ²⁰⁶Pb/²⁰⁴Pb, ²⁰⁷Pb/²⁰⁴Pb and ²⁰⁸Pb/²⁰⁴Pb were measured using a Q-ICP-MS instrument. Two certified refer...
متن کاملLead isotopes as a supplementary tool in the routine evaluation of household lead hazards.
The advent of magnetic sector inductively coupled plasma-mass spectrometry (ICP-MS) allows rapid, accurate, and precise measurement of lead isotopes in environmental and biological samples at a lower cost than traditional methods. This may increase the feasibility of including lead isotope measurements as a routine tool to identify household sources of lead exposure to children. Here, we presen...
متن کاملDetermination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise.
An analytical exercise was initiated in order to determine those procedures with the capability to measure total uranium and uranium (238U/235U) isotopic ratios in urine samples containing >0.02 microg U kg-1 urine. A host laboratory prepared six identical sets of twelve synthetic urine samples containing total uranium in the range of 25 to 770 ng U kg-1 urine and with 238U/235U isotopic ratios...
متن کامل