Development of a detection tablet for a portable NO2 monitoring system.

نویسندگان

  • Gaku Ishiguro
  • Tetsuya Kawabe
  • Nobuo Nakano
  • Kunio Nagashima
چکیده

We have already developed a HCHO monitoring system which is called FP-30. In this experiment, we have developed a NO(2) detection tablet which can be used by the monitoring system. The detection tablet for the NO(2) was constructed with the sensing paper: porous cellulose paper that contains silica gel as an adsorbent, N-1-naphthylethylenediamine dihydrochloride (NED), and glycerin. The NO(2) in sample gas was blown over and adsorbed on the surface of the sensing paper. Then the NO(2) reacted with NED, producing a yellow compound. The coloring reaction took place on the surface of the sensing paper. The degree of color change of paper from white to yellow was monitored as a function of the intensity of the reflected light (lambda = 475 nm) of an LED. The detection limit was 0.01 ppm when the sampling time was 30 min, and the flow rate of sample gas was 250 ml/min. This sensing paper process was not interfered with by acetaldehyde, acetone, alcohols, hydrocarbons, carbon monoxide or carbon dioxide. The NO(2) concentrations in the rooms of a house or school were monitored using this monitoring system and the standard chemiluminescence method. The concentrations of NO(2) monitored by both methods were within 18% of the average. This highly sensitive, selective, and handy NO(2) gas monitoring system will be widely applicable and convenient for users who are not specialists in this field.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

  A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...

متن کامل

Proposed new signal for real-time stress monitoring: Combination of physiological measures

Human stress is a physiological tension that appears when a person responds to mental, emotional, or physical chal-lenges. Detecting human stress and developing methods to manage it, has become an important issue nowadays. Au-tomatic stress detection through physiological signals may be a useful method for solving this problem. In most of the earlier studies, long-term time window was considere...

متن کامل

Low-cost Vector Network Analyzer for Biomedical Applications

A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...

متن کامل

On the use of multi-agent systems for the monitoring of industrial systems

The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences su...

متن کامل

Non-ionizing electromagnetic waves measurement and monitoring Systems

In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 2006