A fast miniature plasma focus based compact and portable nanosecond pulsed neutron source

نویسندگان

  • Rishi Verma
  • R. S. Rawat
  • P. Lee
  • S. V. Springham
  • T. L. Tan
  • M. V. Roshan
  • M. Krishnan
چکیده

A low energy fast miniature plasma focus device ‘FMPF-1’ has recently been developed to be used as compact and portable nanosecond pulsed neutron source for field applications. The system operates in deuterium producing maximum neutron yield in the order of 10 neutrons/ pulse in 4� sr. at ~80kA peak discharge current. In the range of 4 to 7mbar distinct and sharp dip in the current derivative signal indicates strong focusing of plasma column registering subsequent emission of hard x-rays (HXR) followed by neutron pulse. The average time duration (FWHM) of HXR and neutron pulses, obtained using NE102A scintillator photomultiplier detector is about ~15 and ~45ns respectively. The overall dimensions of the apparatus including capacitor bank, spark gap and the focus chamber is 0.2m�0.2m�0.5m and the total weight of system is ~25kg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...

متن کامل

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Small plasma focus as neutron pulsed source for nuclides identification.

In this paper, we present preliminary results on the feasibility of employing a low energy (2 kJ, 31 kV) plasma focus device as a portable source of pulsed neutron beams (2.45 MeV) generated by nuclear fusion reactions D-D, for the "in situ" analysis of substances by nuclear activation. This source has the relevant advantage of being pulsed at requirement, transportable, not permanently radioac...

متن کامل

Neutron Generators Developed at Lbnl for Homeland Security and Imaging Applications*

The Plasma and Ion Source Technology Group at Lawrence Berkeley National Laboratory has developed various types of advanced D-D (neutron energy 2.5 MeV), D-T (14 MeV) and T-T (0–9 MeV) neutron generators for wide range of applications. These applications include medical (Boron Neutron Capture Therapy), homeland security (Prompt Gamma Activation Analysis, Fast Neutron Activation Analysis and Pul...

متن کامل

محاسبه ثابت کالیبراسیون شمارنده فعال‌سازی با پوشش نقره‌ای و مقایسه آن با نتایج تجربی به‌منظور اندازه‌گیری بهره نوترونی در دستگاه پلاسمای کانونی

The silver activation counters are commonly used for pulsed-neutron yield measurements especially in plasma focus devices. The counter normally consists of a Geiger-Muller tube along with silver foils and polyethylene (as a moderator), which is calibrated against an Am-Be radioisotope neutron source. The neutrons, after being slowed-down in the polyethylene, activate the silver foils. By measur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009