Macular pigment density and distribution: comparison of fundus autofluorescence with minimum motion photometry
نویسندگان
چکیده
Macular pigment (MP) distribution profiles were measured for 18 subjects using a Moreland anomaloscope modified for motion photometry. The total amount of MP within the central 7 degrees was estimated from the distribution profile by numerical integration. Fundus autofluorescence images were obtained for eight of these subjects using a scanning laser ophthalmoscope. Peak optical density of MP increased with the total amount present, but the correlation was weakened by inter-subject differences in MP distribution. The mean MP distribution derived from mean grey-scale profiles of fundus autofluorescence images correlated closely with that obtained psychophysically (r=0.96). Autofluorescence imaging provides a fast non-invasive method for assessing MP in vivo.
منابع مشابه
Macular pigment optical density spatial distribution measured in a subject with oculocutaneous albinism.
PURPOSE Previous studies of macular pigment optical density (MPOD) distribution in individuals with oculocutaneous albinism (OCA) have primarily used objective measurement techniques including fundus reflectometry and autofluorescence. We report here on a subject with OCA and their corresponding MPOD distribution assessed through heterochromatic flicker photometry (HFP). METHODS A subject wit...
متن کاملClinical and Epidemiologic Research The Heritability of Macular Response to Supplemental Lutein and Zeaxanthin: A Classic Twin Study
METHODS. A total of 322 healthy female twin volunteers, aged 16–50 years (mean 40 6 8.7) was enrolled in a prospective, nonrandomized supplement study. Macular pigment optical density (MPOD) measurements using two techniques (2wavelength fundus autofluorescence [AF] and heterochromatic flicker photometry [HFP]), and serum concentrations of L and Z, were recorded at baseline, and at 3 and 6 mont...
متن کاملMacular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.
We present a technique for estimating the density of the human macular pigment noninvasively that takes advantage of the autofluorescence of lipofuscin, which is normally present in the human retinal pigment epithelium. By measuring the intensity of fluorescence at 710 nm, where macular pigment has essentially zero absorption, and stimulating the fluorescence with two wavelengths, one well abso...
متن کاملConcordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.
PURPOSE We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). METHODS Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitome...
متن کاملMacular pigment shows ringlike structures.
PURPOSE The spatial distribution of macular pigment is generally assumed to monotonously decrease to very low values in the periphery. However, there are indications that this picture may be too simple. The purpose of this study was to examine the spatial distribution of the macular pigment optical density. METHODS Fundus reflectance and autofluorescence maps at 488 and 514 nm Argon laser wav...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 43 شماره
صفحات -
تاریخ انتشار 2003