Influence of a Scanning Radial Magnetic Field on Macroparticle Reduction of Arc Ion-Plated Films

نویسندگان

  • Shuhao Wang
  • Zeng Lin
  • Hong Qiao
  • Dechun Ba
  • Lida Zhu
چکیده

Cathode spot motion influences the physical characteristics of arc plasma and the related macroparticles (MPs) in resultant films; these MPs limit the application of arc ion plating (AIP). In this paper, a scanning radial magnetic field (SRMF) was applied to the cathode surface to control the cathode spot motion and reduce the MP contamination in the deposited films. It was shown that film surface morphologies prepared using SRMF were better than those using a static radial magnetic field (RMF). The improvement was greater with increased scanning range and frequency. Using SRMF, cathode spot motion was confined to a spiral trajectory on the cathode surface and the spots moved over a large area and at a fast-moving velocity. Both the large moving area and the fast velocity decreased the temperature on the cathode surface and thus reduced the emission of the MPs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Macroparticles in films deposited by steered cathodic arc

The macroparticle content of titanium films deposited using a steered vacuum cathodic arc has been investigated. It has been found that the macroparticle number decreases with increasing steering magnetic field strength, and experimental results are found to be consistent with the model in which the number and mass of macroparticles arising from a cathode spot are proportional to the cathode sp...

متن کامل

Effect of Magnetic Field on Surface Morphology and Magnetic Properties of FeCu/Cu Nano layers Prepared by Electrodeposition Technique: Investigation of Magneto-hydrodynamic Effect

In this paper, the effect of magnetic field on the morphology, structure and magnetic properties of electrodeposited FeCu/Cu thin films was investigated. The films were deposited on Au2PdAg/glass substrates using electrodeposition technique in potentiostatic control. The magnetic fields of 5000 and 7000 Oe were applied on deposition bath during deposition. Two series of thin films were prepared...

متن کامل

Bias and Self-Bias of Magnetic Macroparticle Filters for Cathodic Arc Plasmas

Curved magnetic filters are often used for the removal of macroparticles from cathodic arc plasmas. This study addresses the need to further reduce losses and improving plasma throughput. The central figure of merit is the system coefficient, κ , defined as filtered ion current normalized by the plasma-producing arc current. The coefficient κ is investigated as a function of continuous and puls...

متن کامل

Influence of Ni Deposition and Subsequent N+ Ion Implantation at Different Implantation Energies on Nano-Structure and Corrosion Behavior of 316 Stainless Steels

Nickel films of 300 nm thickness were deposited by electron beam evaporation at room temperature on 316 stainless steels. Corrosion studies of Ni coated 316 SS have been performed after N+ ion implantation at different energies of 20, 40, 60 and 80 keV. The structure and surface morphology of the films were evaluated using X-ray diffraction (XRD), atomic force microscope (AFM) an...

متن کامل

Imaging the separation of cathodic arc plasma and macroparticles in curved magnetic filters

Cathodic vacuum arc plasmas can be used to produce well adherent, dense, highquality films and coatings provided macroparticles are removed from the plasma. Both plasma and macroparticles are produced at cathode spots, and in most cases both can easily be observed because they emit light. The nature of this light emission is briefly discussed. Using open, curved solenoids as magnetic filters, o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2018