A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis
نویسندگان
چکیده
PURPOSE This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Brånemark System® Mk III TiUnite™, Straumann Standard Implant SLA®, and Astra Tech Microthread™-OsseoSpeed™) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Brånemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.
منابع مشابه
Resonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملRadiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation
Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...
متن کاملThe Influence of Site Preparation (Countersinking) on Initial Dental Implant Stability. An in vitro Study Using Resonance Frequency Analysis
Primary implant stability is considered to be a critical factor for obtaining successful osseointegration [1]. Studies using Resonance Frequency Analysis (RFA) have demonstrated that initial implant stability is determined by the density of the bone, the surgical technique used, and the design of the implant [2, 3]. While different implant designs have shown similar results of higher stabilitie...
متن کاملComparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
BACKGROUND The purpose of this study was to compare a parallel wall design implant to a tapered apex design implant when placed in the posterior maxilla using two different surgical protocols. METHODS Twenty-seven patients (30 implants) were divided into three groups. All implants were 4 mm wide in diameter and 8 mm long. Group A received 10 tapered implants (OSPTX) (Astra Tech OsseoSpeed TX™...
متن کاملInfluence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction...
متن کامل