The effects of CO2 on respiratory mechanics in anesthetized paralyzed humans.
نویسندگان
چکیده
BACKGROUND There is little information concerning the carbon dioxide-related effects on respiratory mechanics in anesthetized, paralyzed subjects; however, hypocapnia or hypercapnia is often permitted in patients with severe brain injury or acute respiratory distress syndrome. Therefore, the carbon dioxide dependence of respiratory mechanics in healthy anesthetized, paralyzed subjects was investigated. METHODS Interrupter resistance (Rint), additional tissue viscoelastic resistance (deltaR), and quasi-static elastance (Est) of lung (L) and chest wall were assessed by means of the rapid end-inspiratory occlusion method in two groups of seven healthy paralyzed subjects anesthetized with diazepam or isoflurane. They underwent ventilation with a fixed pattern and hyperoxic gas mixtures with different fractions of inspired carbon dioxide (FICO2) to produce a partial pressures of arterial carbon dioxide (PaCO2) of 24.4 +/- 3.4, 39.6 +/- 3.2, and 62 +/- 4.1 (SD) mmHg. RESULTS Chest wall mechanics and Est,L were unaffected by PaCO2 changes. With diazepam anesthesia, Rint,L decreased linearly, with increasing PaCO2, from 2.3 to 1.4 cm H2O.s.l(-1), whereas deltaR,L decreased from 2 to 1.7 cm H2O.s.l(-1), though not significantly. With isoflurane anesthesia, the decrease of Rint,L (0.2 +/- 0.5 cm H2O.s.l(-1)) was not significant, and deltaRL remained unchanged. With diazepam, Rint,L was 45 (hypercapnia) to 110% (hypocapnia) greater than with isoflurane. CONCLUSIONS Changes of PaCO2 from 20-65 mmHg cause increasing bronchodilation in anesthetized, paralyzed subjects, this effect being attenuated or abolished by drugs (e.g., halogenated anesthetics) that depress smooth muscle tone substantially. The carbon dioxide bronchodilating effects are probably direct for peripheral structures and are paralleled by a tendency of lung tissue resistance to decrease. Because local PaCO2-related changes in bronchomotor tone promote VA/Q matching, this mechanism should be impaired by anesthetics that cause bronchodilation.
منابع مشابه
Laryngeal-receptor responses to phasic CO2 in anesthetized cats.
We compared the effects of CO2 applied continuously and during expiration on laryngeal-receptor activity in paralyzed, artificially ventilated and nonparalyzed, spontaneously breathing cats by using an isolated larynx, artificially ventilated to approximate a normal respiratory cycle. The majority of quiescent negative-pressure and all cold receptors were excited by 5 and 9% CO2 applied both co...
متن کاملRole of carbon dioxide oscillation in the control of respiration in the anesthetized dog.
In order to examine the role of respiratory oscillation of PaCO2 (CO2 oscillation) in the control of respiration, we performed veno-venous bypass using a membrane lung in 10 anesthetized paralyzed dogs, where the dog was put on fixed mechanical ventilation so that we could keep average PaCO2 and PaO2 constant by adjusting FICO2 and FIO2 during CO2 loading/unloading. By venous CO2 loading/unload...
متن کاملRespiratory system mechanics in sedated, paralyzed, morbidly obese patients.
The effects of inspiratory flow and inflation volume on the mechanical properties of the respiratory system in eight sedated and paralyzed postoperative morbidly obese patients (aged 37.6 +/- 11.8 yr who had never smoked and had normal preoperative seated spirometry) were investigated by using the technique of rapid airway occlusion during constant-flow inflation. With the patients in the supin...
متن کاملEnhancement of cerebrovascular effect of CO2 by hypoxia.
Internal carotid blood flow, taken as an index of cerebral blood flow (CBF); arterial pressure; and respiratory O2 and CO2 concentrations, were measured in halothane (1%)-anesthetized, paralyzed and mechanically ventilated rabbits. CBF was determined at end-tidal CO2 of 4% (normocapnia) and 8%, as inspired O2 [O2]I) was varied stepwise over the range of 6.5 to 92%. Normocapnic CBF was constant ...
متن کاملRespiratory mechanics and maximal expiratory flow in the anesthetized mouse.
Mice have been widely used in immunologic and other research to study the influence of different diseases on the lungs. However, the respiratory mechanical properties of the mouse are not clear. This study extended the methodology of measuring respiratory mechanics of anesthetized rats and guinea pigs and applied it to the mouse. First, we performed static pressure-volume and maximal expiratory...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesiology
دوره 94 4 شماره
صفحات -
تاریخ انتشار 2001