Distortions of the posterior surface in optical coherence tomography images of the isolated crystalline lens: effect of the lens index gradient
نویسندگان
چکیده
We quantify the posterior surface distortions in optical coherence tomography (OCT) images of isolated crystalline lenses. The posterior radius of curvature and asphericity obtained from OCT images acquired with the beam incident first on the anterior, and then the posterior, surface were compared. The results were compared with predictions of a ray-tracing model which includes the index gradient. The results show that the error in the radius of curvature is within the measurement reproducibility and that it can be corrected by assuming a uniform refractive index. However, accurate asphericity values require a correction algorithm that takes into account the gradient.
منابع مشابه
Age-dependent variation of the Gradient Index profile in human crystalline lenses.
PURPOSE: To reconstruct the gradient index (GRIN) profile of human crystalline lenses ex-vivo using Optical Coherence Tomography (OCT) imaging with an optimization technique and to study the dependence of the GRIN profile with age. METHODS: Cross-sectional images of nine isolated human crystalline lenses with ages ranging from 6 to 72 (post mortem time 1 to 4 days) were obtained using a custom...
متن کاملInfluence of shape and gradient refractive index in the accommodative changes of spherical aberration in nonhuman primate crystalline lenses.
PURPOSE To estimate changes in surface shape and gradient refractive index (GRIN) profile in primate lenses as a function of accommodation. To quantify the contribution of surface shape and GRIN to spherical aberration changes with accommodation. METHODS Crystalline lenses from 15 cynomolgus monkeys were studied in vitro under different levels of accommodation produced by a stretching system....
متن کاملDistortion correction of OCT images of the crystalline lens: gradient index approach.
PURPOSE To propose a method to correct optical coherence tomography (OCT) images of posterior surface of the crystalline lens incorporating its gradient index (GRIN) distribution and explore its possibilities for posterior surface shape reconstruction in comparison to existing methods of correction. METHODS Two-dimensional images of nine human lenses were obtained with a time-domain OCT syste...
متن کاملRefractive index measurement of the isolated crystalline lens using optical coherence tomography
An optical coherence tomography system has been developed that was designed specifically for imaging the isolated crystalline lens. Cross-sectional OCT images were recorded on 40 lenses from 32 human donors with an age range of 6-82 years. A method has been developed to measure the axial thickness and average refractive index of the lens from a single recorded image. The measured average group ...
متن کاملContribution of shape and gradient refractive index to the spherical aberration of isolated human lenses.
PURPOSE To estimate the contribution of 3-dimensional (3D) lens geometry and gradient refractive index (GRIN) to the lens spherical aberration (SA) with age. METHODS A total of 35 donor human lenses (19-71 years) were imaged with 3D-spectral optical coherence tomography (sOCT). Paraxial and nonparaxial back focal length were measured with laser ray tracing (LRT). The parameters of a 4-variabl...
متن کامل