Determination of optimal electrode positions for tDCS

نویسندگان

  • Chang-Hwan Im
  • Hui-Hun Jung
  • Jung-Do Choi
  • Soo Yeol Lee
  • Ki-Young Jung
چکیده

The present study introduces a new approach to determining optimal electrode positions in transcranial direct current stimulation (tDCS). Electric field and 3D conduction current density were analyzed using 3D finite element method (FEM) formulated for a dc conduction problem. The electrode positions for minimal current injection were optimized by changing the Cartesian coordinate system into the spherical coordinate system and applying the (2+6) evolution strategy (ES) algorithm. Preliminary simulation studies applied to a standard three-layer head model demonstrated that the proposed approach is promising in enhancing the performance of tDCS. (Some figures in this article are in colour only in the electronic version)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Individualized model predicts brain current flow during transcranial direct-current stimulation treatment in responsive stroke patient.

Although numerous published reports have demonstrated the beneficial effects of transcranial direct-current stimulation (tDCS) on task performance, fundamental questions remain regarding the optimal electrode configuration on the scalp. Moreover, it is expected that lesioned brain tissue will influence current flow and should therefore be considered (and perhaps leveraged) in the design of indi...

متن کامل

A sensitive method for electrochemical determination of molybdenum (VI) in plant foodstuff samples using Ni0.5Zn0.5Fe2O4 nanocomposite modified carbon paste electrode

In the present study, a new chemically modified carbon paste electrode (CPE) is constructed for rapid, accurate, simple, highly sensitive, and selective determination of Mo (VI) using differential pulse voltammetry. The electrode was prepared using magnetic nickel zinc ferrite nanocomposite (Ni0.5Zn0.5Fe2O4), as the modifier in CPE (Ni0.5Zn0.5Fe2O4/CPE). Mo (VI) was determined after preconcentr...

متن کامل

Fabrication of an Electrochemical Sensor Based on a New Nano-ion Imprinted Polymer for Highly Selective and Sensitive Determination of Molybdate

In this work a new chemically modified carbon paste electrode was constructed for accurate, simple, sensitive and selective determination of molybdenum (VI) ions. The results of modified electrode by an ion imprinted polymer were compared with those obtained with carbon paste electrode. The results showed the stripping peak currents had a dramatic increase at the modified electrode. Under the o...

متن کامل

An application of simulated annealing to optimal transcranial direct current stimulation of the human brain

Transcranial direct current stimulation (tDCS) is known as the most effective technique for stimulating deeper brain areas. The capability of tDCS, however, strongly depends on the number of electrodes, their positions, and the amount of injected currents. This paper intends to apply the simulated annealing algorithm for determining optimal stimulation parameters in a multiple electrode scheme....

متن کامل

Selective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)

   Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008