Upfront dilution of ferritin samples to reduce hook effect, improve turnaround time and reduce costs

نویسندگان

  • Shu Juan Wu
  • Joshua A. Hayden
چکیده

Introduction Sandwich immunoassays offer advantages in the clinical laboratory but can yield erroneously low results due to hook (prozone) effect, especially with analytes whose concentrations span several orders of magnitude such as ferritin. This study investigated a new approach to reduce the likelihood of hook effect in ferritin immunoassays by performing upfront, five-fold dilutions of all samples for ferritin analysis. The impact of this change on turnaround time and costs were also investigated. Materials and methods Ferritin concentrations were analysed in routine clinical practice with and without upfront dilutions on Siemens Centaur® XP (Siemens Healthineers, Erlang, Germany) immunoanalysers. In addition, one month of baseline data (1026 results) were collected prior to implementing upfront dilutions and one month of data (1033 results) were collected after implementation. Results Without upfront dilutions, hook effect was observed in samples with ferritin concentrations as low as 86,028 µg/L. With upfront dilutions, samples with ferritin concentrations as high as 126,050 µg/L yielded values greater than the measurement interval and would have been diluted until an accurate value was obtained. The implementation of upfront dilution of ferritin samples led to a decrease in turnaround time from a median of 2 hours and 3 minutes to 1 hour and 18 minutes (P = 0.002). Conclusions Implementation of upfront dilutions of all ferritin samples reduced the possibility of hook effect, improved turnaround time and saved the cost of performing additional dilutions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories

Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...

متن کامل

Synergistic Effect of Silver Nanoparticles and Streptomycin Antibiotic on the MexX Gene Expression of Pump Efflux System in Drug-Resistant Pseudomonas aeruginosa Strains

Introduction: Pseudomonas aeruginosa is one of the most important infectious agents in humans, which is difficult to control in hospitals due to its resistance to various antibiotics. Efflux pump systems play an important role in the drug resistance of this bacterium to a variety of antibiotics. This study aimed to determine the antimicrobial synergistic effect of silver nanoparticles and the a...

متن کامل

ELISA Analyzer •, a Software to Analyze and Optimize ELISA Data

ELISA data is usually handled in the MS Excel worksheets through different methods and different formulas. Accurate and precise calculations of the data is time consuming and tedious. ELISA Analyzer was developed with a user friendly interface to streamline titration and analysis of the data obtained from ELISA and improve rapid and lucid presentation of the results. The software can also hel...

متن کامل

Development and Evaluation of a Laboratory Information System-Based Auto-Dilution and Manual Dilution Algorithm for Alpha-Fetoprotein Assay

Korea is known as a hepatitis B virus-endemic area with a high incidence of hepatocellular carcinoma (HCC) [1]. Alpha-fetoprotein (AFP) is the most widely used tumor marker for monitoring HCC in clinical practices. The serum AFP level is <10 ng/mL in healthy adults, but patients with HCC show a very wide distribution of AFP levels. AFP level is known to increase in 60-70% of patients with HCC [...

متن کامل

Interference Mitigation of Replay Attacks in GPS Receiver using of Finite Impulse Response Filter

The vulnerability of civil GPS receiver to interference may be intentional or unintentional. Among all types of interference, replay attack intended as the most dangerous intentional one. The signal structure of replay attack is almost the same with the satellite signal. The interference effects can be reduce with the design of an appropriate filter in the receiver. This paper presents two meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2018