Optimization and Validation of High-Performance Chromatographic Condition for Simultaneous Determination of Adapalene and Benzoyl Peroxide by Response Surface Methodology
نویسندگان
چکیده
The aim of this study was to develop a simple and reliable high-performance chromatographic (HPLC) method for simultaneous analysis of adapalene and benzoyl peroxide in pharmaceutical formulation by response surface methodology (RSM). An optimized mobile phase composed of acetonitrile, tetrahydrofuran and water containing 0.1% acetic acid at a ratio of 25:50:25 by volume was successfully predicted by using RSM. An isocratic separation was achieved by using the condition. Furthermore, the analytical method was validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentration. Finally, the method was successfully applied to the analysis of a commercial product.
منابع مشابه
Efficacy and tolerability of adapalene 0.1%-benzoyl peroxide 2.5% combination gel in treatment of acne vulgaris in Indian patients: A randomized investigator-blind controlled trial
Background: Topical retinoid based combinations are recommended to enhance the outcome of acne treatment. Adapalene-benzoyl peroxide (BPO) combination gel was approved in 2009 for acne treatment. The aim of this study was to evaluate the efficacy and tolerability of adapalene 0.1%-benzoyl peroxide 2.5% combination gel compared to adapalene 0.1% gel monotherapy and benzoyl peroxide 2.5% gel mono...
متن کاملProcess optimization for ethanol production from very high gravity (VHG) finger millet medium using response surface methodology
The Box-Wilson central composite design (CCD) based on response surface methodology (RSM) was used for ethanol fermentation using very high gravity (VHG) finger millet hydrolysate. Optimized process variables were namely, concentrations of yeast extract, magnesium sulphate and pH of the medium. High gravity mashes (>300 g dissolved solids per liter) were prepared by a thermo-stable α-amylase, f...
متن کاملApplication of the Response Surface Methodology for the Optimization of the Aqueous Enzymatic Extraction of Pistacia Khinjuk Oil
ABSTRACT: Aqueous enzymatic extraction of oil from pistacia khinjuk was performed using cellulase. The central composite design was used to optimize the parameters that are significant to the process. The influence of three regressors on the percentage of oil recovery from seed was evaluated using second-order polynomial multiple regression model. Analysis of variance showed a high coefficient ...
متن کاملValidated Stability-Indicating RP-HPLC Method for the Estimation of Degradation Behaviour of Organic Peroxide and Third-Generation Synthetic Retinoids in Topical Pharmaceutical Dosage Formulation.
The objective of the current study was to establish a validated stability-indicating, high-performance liquid chromatographic method to determine the purity of benzoyl peroxide (BPO) and adapalene (ADP) in the presence of its impurities, forced degradation products, and placebo in pharmaceutical dosage forms. The desired chromatographic separation was achieved on the Kinetex(™) C18 (250 × 4.6 m...
متن کاملApplication of Response Surface Methodology as an Efficient Approach for Optimization of Operational Variables in Benzene Hydroxylation to Phenol by V/SBA-16 Nanoporous Catalyst
Herein, we prepared a V/SBA-16 catalyst using vanadyl acetylacetonate as a precursor and SBA-16 nanoporous silica as a support via an immobilization technique. The ordered mesoporous structure of catalyst was determined by X-ray diffraction and transmission electron microscopy techniques , and the catalyst was evaluated in the benzene hydroxylation to phenol with hydrogen peroxide (H2O2) as a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -