Prevalence and severity of renal dysfunction among 1062 heart transplant patients according to criteria based on serum creatinine and estimated glomerular filtration rate: results from the CAPRI study.

نویسندگان

  • Maria G Crespo-Leiro
  • Juan F Delgado
  • Maria J Paniagua
  • Jose A Vázquez de Prada
  • Juan Fernandez-Yañez
  • Luis Almenar
  • Beatriz Diaz-Molina
  • Eulalia Roig
  • Jose M Arizón
  • Luis Alonso-Pulpón
  • Iris P Garrido
  • Maria Luisa Sanz
  • Luis de la Fuente
  • Sonia Mirabet
  • Nicolas Manito
  • Javier Muñiz
چکیده

Chronic kidney disease (CKD) is staged on the basis of glomerular filtration rate; generally, the MDRD study estimate, eGFR, is used. Renal dysfunction (RD) in heart transplant (HT) patients is often evaluated solely in terms of serum creatinine (SCr). In a cross-sectional, 14-center study of 1062 stable adult HT patients aged 59.1±12.5 yr (82.3% men), RD was graded as absent-or-mild (AoM), moderate, or severe (this last including dialysis and kidney graft) by two classifications: SCr-RD (SCr cutoffs 1.6 and 2.5 mg/dL) and eGFR-RD (eGFR cutoffs 60 and 30 mL/min/1.73 m2). SCr-RD was AoM in 68.5% of patients, moderate in 24.9%, and severe in 6.7%; eGFR-RD, AoM in 38.6%, moderate in 52.2%, severe in 9.2%. Among patients evaluated <2.7, 2.7-6.2, 6.2-9.5 and >9.5 yr post-HT (the periods defined by time-since-transplant quartiles), AoM/moderate/severe RD prevalences were <2.7, SCr-RD 74/21/5%, eGFR-RD 47/47/6%; 2.7-6.2, SCr-RD 73/22/5%, eGFR-RD 37/56/7%; 6.2-9.5, SCr-RD 69/24/7%, eGFR-RD 37/54/9%; >9.5, SCr-RD 58/32/10%, eGFR-RD 32/52/16%. The prevalence of severe RD increases with time since transplant. If the usual CKD stages are appropriate for HT patients, the need for less nephrotoxic immunosuppressants and other renoprotective measures is greater than is suggested by direct SCr-based grading, which should be abandoned as excessively insensitive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels

Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...

متن کامل

Comparison of Serum Cystatin C and Creati-nine Levels to Evaluate Early Renal Function after Kidney Transplantation

Background: Accurate and rapid assessment of allograft function is essential in renal transplant recipients in order to detect allograft rejection and to monitor drug nephrotoxicity. We aimed to evaluate the usefulness of cystatin C as a marker of kidney allograft function in the early post-transplant period and to compare this value with that of conventional serum creatinine concentration. Met...

متن کامل

Early Acute Kidney Injury based on Serum Creatinine or Cystatin C in Intensive Care Unit after Major Trauma

Background: Acute kidney injury (AKI) is a common problem in critically ill patients and is independently associated with increased morbidity and mortality. Recently, serum cystatin C has been shown to be superior to creatinine in early detection of renal function impairment. We compared estimated GFR based on serum cystatin C with estimated GFR based on serum creatinine for early detection of ...

متن کامل

Glomerular filtration rate determination by creatinine and cystatin-C in patients with acute pyelonephritis

Background: Measurement of glomerular filtration rate (GFR) and monitoring of it in any patient on nephrotoxic drugs is very important. Recently, cystatin C (cys-C) has been introduced as a better marker for determining and monitoring renal function than creatinine especially in a mild decrease of GFR. This study was done to assess the change of GFR measurement based on serum Cys-C and creatini...

متن کامل

بررسی ارتباط میزان فیلتراسیون گلومرولی (GFR) با عملکرد کبد در بیماران سیروز کبدی

Background and purpose: Serum creatinine and its derived formulae in estimating glomerular filtration rate is not accurate in cirrhotic patients because of decreased muscle mass and secretion and excretion functional impairment of liver. This study aimed at investigating the accuracy of serum cystatin C in determining GFR and examining the relationship between synthetic and excretory liver func...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical transplantation

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2010