Electrode measurement of glucose and urea in undiluted samples.

نویسندگان

  • Y Gourmelin
  • B Gouget
  • A Truchaud
چکیده

The development of ion-selective electrodes (ISEs) for electrolyte measurements necessitates a re-evaluation of the biological and clinical interpretation of a result. In pathological situations (e.g., hyperlipidemia and hyperproteinemia) direct potentiometry is the method of choice for ion measurements in blood. However, the "plasma water effect" exists also in normal samples, requiring new reference values for physiological ranges. A compromise between medical and instrumentation workers retained the old reference values (flame photometry for Na+ and K+) by introducing correction factors into the ISE instruments, so that the results for direct ISE and flame photometry are the same for "normal" samples. Analyses of "abnormal" samples will reveal biases between the two methods. Now, a new generation of electrodes for assaying additional metabolites reopens the issue. Although classical methods measure a quantity of substance in a predetermined volume of sample, the majority of the substance is usually in the aqueous phase, and the volumes occupied by lipid and protein are not taken into consideration. In evaluating the NOVA 12 instrument (NOVA Biomedical), using electrodes for direct measurement in serum or plasma of Na, K, Cl, total CO2, urea, and glucose, we have demonstrated the inadequacy of classical measurements of urea and glucose, especially in pathological situations characterized by a large variation in the plasma water fraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New in vitro analytical approaches for clinical chemistry measurements in critical care.

The effective management of patients in intensive care units, operating rooms, and emergency rooms requires frequent measurement of a select group of analytes, preferably at or near the patient's bedside. Tests recognized as being essential for such management include blood gases and related variables (pH, pO2, pCO2, HCO3-, hematocrit/hemoglobin, O2 saturation), electrolytes (Na+, K+, Ca2+, Cl-...

متن کامل

Clinical evaluation of amperometric enzyme electrodes in continuous-flow analysis for glucose in undiluted whole blood.

We have evaluated the carbon-paste enzyme/wall-jet electrode in continuous-flow analysis for glucose in undiluted whole blood. Responses of the electrode to protein-based and aqueous samples under wall-jet configuration are described. Imprecision in the flow-injection mode was less than 2% for glucose values in the usual analytical range (1-25 mmol/L). The dynamic range for glucose was from 0.0...

متن کامل

Immobilized glucose oxidase used to measure glucose in serum.

We report an analytical system in which glucose oxidase immobilized on controlled-pore glass is used. The immobilized glucose oxidase was packed in a column that was part of a continuous-flow system. Oxygen depletion of the buffer was measured with a Clark-type electrode, and the resulting data were stored on tape and then evaluated with a PDP-12 computer. The relative advantages of several mea...

متن کامل

A kinetic assay for urea in undiluted urine specimens.

We describe a kinetic assay for quantifying urea in undiluted urine samples. The assay linearity extends to urea concentrations of 400 mmol/L, is free from interference from blood (10 mL/L) or bilirubin (1 mmol/L), is sufficiently precise for routine use, and correlates well with an established method for assay of diluted urine samples.

متن کامل

Near-infrared spectroscopy for measuring urea in hemodialysis fluids.

BACKGROUND Near-infrared spectroscopy is proposed as a method for providing real-time urea concentrations during hemodialysis treatments. The feasibility of such noninvasive urea measurements is evaluated in undiluted dialysate fluid. METHODS Near-infrared spectra were collected from calibration solutions of urea prepared in dialysate fluid. Spectra were collected over three distinct spectral...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 9  شماره 

صفحات  -

تاریخ انتشار 1990