99mTc-N-DBODC5, a new myocardial perfusion imaging agent with rapid liver clearance: comparison with 99mTc-sestamibi and 99mTc-tetrofosmin in rats.

نویسندگان

  • Kengo Hatada
  • Laurent M Riou
  • Mirta Ruiz
  • Yoshihiro Yamamichi
  • Adriano Duatti
  • Ronaldo L Lima
  • Allen R Goode
  • Denny D Watson
  • George A Beller
  • David K Glover
چکیده

UNLABELLED (99m)Tc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of (99m)Tc-N-DBODC5 with (99m)Tc-sestamibi and (99m)Tc-tetrofosmin. METHODS Seventy-five anesthetized Sprague-Dawley rats were injected intravenously with 22.2-29.6 MBq (99m)Tc-N-DBODC5 (n = 25), (99m)Tc-sestamibi (n = 25), or (99m)Tc-tetrofosmin (n = 25). Rats were euthanized at either 2, 10, 20, 30, or 60 min after injection and gamma-well counting was performed on excised organ (heart, lung, and liver) and blood samples. In 3 additional rats, serial in vivo whole-body gamma-camera imaging with each tracer was performed. RESULTS (99m)Tc-N-DBODC5 cleared rapidly from the blood pool. At 2 min after injection, (99m)Tc-N-DBODC5 blood activity was significantly lower than either (99m)Tc-sestamibi or (99m)Tc-tetrofosmin (P < 0.01) and remained lower over 60 min. Myocardial (99m)Tc-N-DBODC5 uptake was rapid (2.9% +/- 0.1% injected dose/g at 2 min), and there was no significant clearance over 60 min, similar to (99m)Tc-sestamibi and (99m)Tc-tetrofosmin. All 3 tracers exhibited rapid lung clearance. Importantly, (99m)Tc-N-DBODC5 cleared more rapidly from the liver than either (99m)Tc-sestamibi or (99m)Tc-tetrofosmin. As early as 30 min after injection, (99m)Tc-N-DBODC5 heart-to-liver ratio was 5.7 +/- 1.0 versus 1.6 +/- 0.1 and 2.9 +/- 0.3 for (99m)Tc-sestamibi and (99m)Tc-tetrofosmin (P < 0.05). By 60 min, (99m)Tc-N-DBODC5 heart-to-liver ratio further increased to 18.4 +/- 2.0 compared with 2.6 +/- 0.2 and 5.8 +/- 0.7 for (99m)Tc-sestamibi and (99m)Tc-tetrofosmin (P < 0.001). The rapid blood pool, lung, and liver clearance of (99m)Tc-N-DBODC5 resulted in excellent-quality myocardial images within 30 min after injection. CONCLUSION (99m)Tc-N-DBODC5 is a promising new myocardial perfusion tracer with superior biodistribution properties. The rapid (99m)Tc-N-DBODC5 liver clearance may shorten the duration of imaging protocols by allowing earlier image acquisition and may markedly reduce the problem of photon scatter from the liver into the inferoapical wall on myocardial images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

99mTc-Tetrofosmin in Rats

99mTc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of 99mTc-N-DBODC5 with 99mTc-sestamibi and 99mTc-tetrofosmin. Methods: Seventy-five anesthetized Sprague–...

متن کامل

Comparison of 99mTc-N-DBODC5 and 99mTc-MIBI of Myocardial Perfusion Imaging for Diagnosis of Coronary Artery Disease

Despite recent advances in therapeutic and diagnostic approaches, coronary artery disease (CAD) and its related cardiac disorders represent the most common cause of death in the United States. Nuclear myocardial perfusion imaging (MPI) technologies play a pivotal role in the diagnosis and treatment design for CAD. Recently, in order to develop improved MPI agents for diagnosis of CAD, (99m)Tc-[...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection.

OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging qua...

متن کامل

Subcellular distribution and metabolism studies of the potential myocardial imaging agent [99mTc(N)(DBODC)(PNP5)]+.

UNLABELLED 99mTc(N)-DBODC5 is the lead compound of a new series of monocationic 99mTc(N)-based potential myocardial imaging agents that exhibit original biodistribution properties. This study was addressed to elucidate the mechanisms of distribution, retention, and elimination of this promising 99mTc(N)-agent. METHODS The sex-related in vitro and in vivo stability and the subcellular distribu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 12  شماره 

صفحات  -

تاریخ انتشار 2004