Prospective correlation of arterial vs venous blood gas measurements in trauma patients.

نویسندگان

  • Scott E Rudkin
  • Christopher A Kahn
  • Jennifer A Oman
  • Matthew O Dolich
  • Shahram Lotfipour
  • Stephanie Lush
  • Marla Gain
  • Charmaine Firme
  • Craig L Anderson
  • Mark I Langdorf
چکیده

OBJECTIVE The objective of this study is to assess if venous blood gas (VBG) results (pH and base excess [BE]) are numerically similar to arterial blood gas (ABG) in acutely ill trauma patients. METHODS We prospectively correlated paired ABG and VBG results (pH and BE) in adult trauma patients when ABG was clinically indicated. A priori consensus threshold of clinical equivalence was set at ± less than 0.05 pH units and ± less than 2 BE units. We hypothesized that ABG results could be predicted by VBG results using a regression equation, derived from 173 patients, and validated on 173 separate patients. RESULTS We analyzed 346 patients and found mean arterial pH of 7.39 and mean venous pH of 7.35 in the derivation set. Seventy-two percent of the paired sample pH values fell within the predefined consensus equivalence threshold of ± less than 0.05 pH units, whereas the 95% limits of agreement (LOAs) were twice as wide, at -0.10 to 0.11 pH units. Mean arterial BE was -2.2 and venous BE was -1.9. Eighty percent of the paired BE values fell within the predefined ± less than 2 BE units, whereas the 95% LOA were again more than twice as wide, at -4.4 to 3.9 BE units. Correlations between ABG and VBG were strong, at r(2) = 0.70 for pH and 0.75 for BE. CONCLUSION Although VBG results do correlate well with ABG results, only 72% to 80% of paired samples are clinically equivalent, and the 95% LOAs are unacceptably wide. Therefore, ABG samples should be obtained in acutely ill trauma patients if accurate acid-base status is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of central venous and arterial blood gas measurements in mechanically ventilated trauma patients.

HYPOTHESIS Central venous blood gas (VBG) measurements of pH, PCO2, and base excess can be substituted for the same values obtained from an arterial blood gas (ABG) analysis in mechanically ventilated trauma patients, obviating the need for arterial puncture. DESIGN AND SETTING Prospective comparison of 99 sets of VBGs and ABGs at a level 1 academic trauma center. PATIENTS A consecutive sam...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

VBG Vs ABG in DKA Patients

BACKGROUND: Diabetic ketoacidosis (DKA) is a life-threatening endocrine emergency, traditionally requiring arterial blood gas (ABG) analysis for diagnosis and monitoring. The aim of our study was to assess the comparability of arterial and venous blood samples for pH and bicarbonate measurements in patients with DKA. MATERIALS AND METHODS: Prospective, observational study of patients with suspe...

متن کامل

Correlation between peripheral venous and arterial blood gas measurements in patients admitted to the intensive care unit: A single-center study

BACKGROUND The objective of this study was to examine the correlation between arterial blood gas (ABG) and peripheral venous blood gas (VBG) samples for all commonly used parameters in patients admitted to a medical intensive care unit (ICU). METHODS A single-center, prospective trial was carried out in a medical ICU in order to determine the level of correlation of ABG and peripheral VBG mea...

متن کامل

مقایسه دی اکسیدکربن انتهای بازدمی و شریانی در بیماران کاندید پیوند عروق کرونر

Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of emergency medicine

دوره 30 8  شماره 

صفحات  -

تاریخ انتشار 2012