Inter- and intra-observer agreement of the AO classification for operatively treated distal radius fractures

نویسندگان

  • Jesse M. van Buijtenen
  • Mischa L. C. van Tunen
  • Wietse P. Zuidema
  • Emile A. Heilbron
  • Jeroen de Haan
  • Henrica C. W. de Vet
  • Robert J. Derksen
چکیده

The reproducibility of the AO classification for distal radius fractures remains a topic of debate. Previous studies showed variable reproducibility results. Important treatment decisions depend on correct classification, especially in comminuted, intra-articular fractures. Therefore, reliable reproducibility results need to be undisputedly determined. Hence, the study objective was to assess inter- and intra-observer agreement of the AO classification for operatively treated distal radius fractures. A database of 54 radiographs of all AO types (A, B and C) and groups (A2-3, B1-3, and C1-3) of distal radius fractures was assessed in twofold. Likewise, a subset of 152 radiographs of solely C-type groups (C1-3) was assessed. All fractures were classified by six observers with different experience levels: three consultant trauma surgeons, one sixth-year trauma surgery resident, a consultant trauma radiologist, and an intern with limited experienced. The inter-observer agreement of both main types and groups was moderate (κ = 0.49 resp. κ = 0.48) in combination with a good intra-observer agreement (κ = 0.68 resp. κ = 0.70). The inter-observer agreement of the subset C-type fractures group was fair (κ = 0.27) with moderate intra-observer agreement (κ = 0.43). According to these results, the reproducibility of the AO classification of main types and groups of distal radius fractures based on conventional radiographs is insufficient (κ < 0.50), especially at group level of C-type fractures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is it time to revisit the AO classification of fractures of the distal radius? Inter- and intra-observer reliability of the AO classification.

We conducted an observational radiographic study to determine the inter- and intra-observer reliability of the AO classification of fractures of the distal radius. Plain posteroanterior and lateral radiographs of 456 patients with an acute fracture of the distal radius were classified by a consultant orthopaedic hand specialist and two specialist trainees, and the k coefficient for the inter- a...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

Are classifications of proximal radius fractures reproducible?

BACKGROUND Fractures of the proximal radius need to be classified in an appropriate and reproducible manner. The aim of this study was to assess the reliability of the three most widely used classification systems. METHODS Elbow radiographs images of patients with proximal radius fractures were classified according to Mason, Morrey, and Arbeitsgemeinschaft für osteosynthesefragen/Association ...

متن کامل

Intra- and Inter-observer Agreement in the Ao and Garnavos Systems for Diaphyseal Humerus Fracture

OBJECTIVE The objective of this study was to compare inter- and intra-observer agreement using the Garnavos and AO/ASIF systems for classifying humeral diaphysis fractures . METHODS Eighty X-ray images taken of humeral diaphysis fractures in adult patients (age≥18 years) between January 2013 and September 2015 in the Radiology Department of Hospital São Paulo were selected for subsequent clas...

متن کامل

Internal plate fixation versus plaster in displaced complete articular distal radius fractures, a randomised controlled trial

BACKGROUND Of all distal radius fractures, 25 % are complete articular fractures (AO/OTA type C fractures). Two thirds of those fractures are displaced and require reduction. According to several International Guidelines, adequately reduced intra-articular distal radius fractures are best treated non-operatively with plaster immobilisation, while surgical fixation is suggested only when the art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015