A gamma-distribution convolution model of 99mTc-MIBI thyroid time-activity curves
نویسندگان
چکیده
BACKGROUND The convolution approach to thyroid time-activity curve (TAC) data fitting with a gamma distribution convolution (GDC) TAC model following bolus intravenous injection is presented and applied to 99mTc-MIBI data. The GDC model is a convolution of two gamma distribution functions that simultaneously models the distribution and washout kinetics of the radiotracer. The GDC model was fitted to thyroid region of interest (ROI) TAC data from 1 min per frame 99mTc-MIBI image series for 90 min; GDC models were generated for three patients having left and right thyroid lobe and total thyroid ROIs, and were contrasted with washout-only models, i.e., less complete models. GDC model accuracy was tested using 10 Monte Carlo simulations for each clinical ROI. RESULTS The nine clinical GDC models, obtained from least counting error of counting, exhibited corrected (for 6 parameters) fit errors ranging from 0.998% to 1.82%. The range of all thyroid mean residence times (MRTs) was 212 to 699 min, which from noise injected simulations of each case had an average coefficient of variation of 0.7% and a not statistically significant accuracy error of 0.5% (p = 0.5, 2-sample paired t test). The slowest MRT value (699 min) was from a single thyroid lobe with a tissue diagnosed parathyroid adenoma also seen on scanning as retained marker. The two total thyroid ROIs without substantial pathology had MRT values of 278 and 350 min overlapping a published 99mTc-MIBI thyroid MRT value. One combined value and four unrelated washout-only models were tested and exhibited R-squared values for MRT with the GDC, i.e., a more complete concentration model, ranging from 0.0183 to 0.9395. CONCLUSIONS The GDC models had a small enough TAC noise-image misregistration (0.8%) that they have a plausible use as simulations of thyroid activity for querying performance of other models such as washout models, for altered ROI size, noise, administered dose, and image framing rates. Indeed, of the four washout-only models tested, no single model approached the apparent accuracy of the GDC model using only 90 min of data. Ninety minutes is a long gamma-camera acquisition time for a patient, but a short a time for most kinetic models. Consequently, the results should be regarded as preliminary.
منابع مشابه
Percutaneous microwave ablation of thyroid nodules: efficacy evaluation with 99m Tc - pertechnetate and 99mTc-MIBI functional imaging
Background: Local ablative treatments play an important role for patients who cannot be treated surgically. Radiofrequency ablation is a well-established alternative to surgical treatment of thyroid nodules, however it also has disadvantages. Microwave ablation (MWA) is a new minimally invasive treatment promising several improvements. The aim of this retrospective study was to evaluate the eff...
متن کاملNegative 99mTc-MIBI uptake in a parathyroid carcinoma: A case report
A 34 year old woman with malaise, polyuria and nocturia as well as nausea and vomiting referred to perform a thyroid scan due to right thyroid lobe mass. The scan showed a cold nodule in the right thyroid lobe. Serum calcium of 16.9, serum phosphorus of 1.8 and PTH of 1156 were noticed in laboratory tests. Parathyroid scan with 99mTc-MIBI showed no abnormal tracer activity in the nec...
متن کاملEvaluation of single cold thyroid nodule with 99mTc-Sestamibi [Persian]
In 30 patient with single cold thyroid nodule and normal thyroid function tests, 99mTc-MIBI scan is performed. The nodules are divided to hot (10), Warm (12) and cold (8). FNA reported papillary Ca in 4, suspicious follicular neoplasm in 3 and 23 benign lesions. 7 patients were operated on and had final pathology reports (4 papillary Ca and 3 benign lesions). All the nodules with no MIBI ...
متن کاملDiagnostic Value of Semiquantitative Analysis of 99mTechnetium-Methoxyisobutylisonitrile (99mTc-MIBI Imaging in Predicting Early-Stage Cervical Lymph Node Metastasis of Thyroid Carcinoma
BACKGROUND The aim of this study was to evaluate the value of semiquantitative analysis (SQA) of 99mTc-MIBI imaging in predicting early-stage cervical lymph node metastasis (CLNM) in thyroid carcinoma (TC). MATERIAL AND METHODS TC patients (n =106) undergoing surgical resection and histopathological examination were enrolled. All patients received 99mTc-MIBI imaging prior to surgery. P-glycopro...
متن کاملAbsent radiotracer uptake in thyroid gland in parathyroid scintigraphy with 99mTc-MIBI: A case report
Localization of 99mTc- hexakis-2-methoxyisobutylisonitrile (99mTc-MIBI) by parathyroid adenomas is well known, and this warrants MIBI scan to evaluate suspected parathyroid adenoma in primary hyperparathyroidism. Typically, the radionuclide concentrates in both the thyroid gland and parathyroid adenoma in early images, and later on delayed images washes out slowly from the...
متن کامل