Pregnancy and variations of carbohydrate-deficient transferrin levels measured by the candidate reference HPLC method.
نویسندگان
چکیده
AIMS Contrasting data are available on the diagnostic accuracy of carbohydrate-deficient transferrin (CDT) during pregnancy. These differences may depend in part on how CDT was evaluated and expressed. Here, we report on variations of CDT levels in pregnant women using the high performance liquid chromatography (HPLC) candidate reference method. METHODS Alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, mean corpuscular volume, serum transferrin, urine and serum ethyl glucuronide and CDT were measured in 64 women, self-reporting as non-alcohol abusers (age: median 34, IQR: 28-38), at different stages of normal pregnancy (gestational weeks: median 28, IQR: 8-33). CDT was expressed as percentage of disialotransferrin to total transferrin (%CDT). RESULTS Transferrin was associated with both %CDT (r = 0.66; P < 0.001) and gestational week (r = 0.68; P < 0.001). Interestingly, %CDT was highly correlated with gestational week (r = 0.77; P < 0.001), even after controlling for the effect of transferrin. Moreover, statistically significant differences in %CDT were also evident between women grouped for pregnancy trimester (first trimester: mean 1.01% (SD 0.19); second trimester: 1.30% (SD 0.14); third trimester: 1.53% (SD 0.22); ANOVA P < 0.001). Trend analysis confirmed a proportional increase of %CDT along with pregnancy trimesters (P < 0.001). CONCLUSIONS %CDT, measured with the HPLC candidate reference method, is independently associated with gestational week. Differently from what has been previously reported or expected, the relationship between pregnancy and CDT could be more complex. The diagnostic accuracy of CDT for detecting alcohol abuse in a legal context may be limited in pregnant women and the effect of gestational age should be considered.
منابع مشابه
DIAGNOSIS AND ASSESSMENT Pregnancy and Variations of Carbohydrate-Deficient Transferrin Levels Measured by the Candidate Reference HPLC Method
Aims: Contrasting data are available on the diagnostic accuracy of carbohydrate-deficient transferrin (CDT) during pregnancy. These differences may depend in part on how CDT was evaluated and expressed. Here, we report on variations of CDT levels in pregnant women using the high performance liquid chromatography (HPLC) candidate reference method. Methods: Alanine aminotransferase, aspartate ami...
متن کاملHuman Serum Transferrin Glycosylation Pattern – Population Differences, Analytical Methodology and Application as Biomarker for Testing of Alcohol Abuse and Cdg
Alcohol use and abuse is a major social and economic problem in many societies. Carbohydrate-deficient transferrin (CDT) is a widely used and highly specific biochemical alcohol marker of prolonged alcohol abuse. Increased knowledge about the clinical characteristics of CDT may lead to better possibilities of employing CDT as a biochemical alcohol marker of risky and heavy alcohol consumption a...
متن کاملCarbohydrate-deficient transferrin measured by high-performance liquid chromatography and CDTect immunoassay.
Carbohydrate-deficient transferrin (CDT) was measured in three populations using anion-exchange chromatography followed by radioimmunoassay (CDTectTM) and a new high-performance liquid chromatography (HPLC) method. The correlation between the methods in 50 consecutive clinical samples was good (r = 0.87). However, in a set of 49 samples with CDT concentrations close to the reference value of th...
متن کاملToward standardization of carbohydrate-deficient transferrin (CDT) measurements: II. Performance of a laboratory network running the HPLC candidate reference measurement procedure and evaluation of a candidate reference material.
Carbohydrate-deficient transferrin (CDT) is a descriptive term used for a temporary change in the transferrin glycosylation profile caused by alcohol, and used as a biomarker of chronic high alcohol consumption. The use of an array of methods for measurement of CDT in various absolute or relative amounts, and sometimes covering different transferrin glycoforms, has complicated the comparability...
متن کاملQuantification of carbohydrate-deficient transferrin by ion-exchange chromatography with an enzymatically prepared calibrator.
The current HPLC method for the determination of carbohydrate-deficient transferrin (CDT) yields ratios of CDT isoforms in relation to total transferrin, whereas the use of absolute concentrations obtainable in routine analysis by RIA and the reference ranges based here-upon is more convenient. We describe a modified HPLC method that likewise gives absolute CDT concentrations by using a calibra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Alcohol and alcoholism
دوره 46 2 شماره
صفحات -
تاریخ انتشار 2011