Contamination risk of stable isotope samples during milling.

نویسندگان

  • M Isaac-Renton
  • L Schneider
  • K Treydte
چکیده

RATIONALE Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. METHODS We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. RESULTS A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. CONCLUSIONS A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Population monitoring: experience with residents exposed to uranium mining/milling waste.

More emphasis should be placed upon using biomarkers to address potential health risk among populations exposed to high concentrations of environmental toxicants. Among these studies, those which integrate exposure measurements with analyses of validated biomarkers may provide more reliable information for risk assessment and disease prevention. We have used a multidisciplinary approach to eluc...

متن کامل

Sensitivity of whole wood stable carbon and oxygen isotope values to milling procedures.

RATIONALE Milling of wood samples is a widely applied preparation method for pooling tree-rings from different trees or periods of several years for determination of δ(13)C and δ(18)O values. In this study, whole wood samples were milled using different procedures in order to evaluate potential effects of this preparation method on δ(13)C and δ(18)O values. METHODS Subsamples of a 5 cm(3) woo...

متن کامل

Impact of durum wheat milling on deoxynivalenol distribution in the outcoming fractions.

The milling behaviour of two naturally infected samples of durum wheat grain with contrasting levels of mycotoxins was studied. Although the two samples showed a similar milling behaviour, an increase of approximately 20% in deoxynivalenol (DON) levels was found in semolina from the sample containing the higher level of mycotoxin. However, even if the highest concentration of DON was found in f...

متن کامل

Impact of contamination and pre-treatment on stable carbon and nitrogen isotopic composition of charred plant remains

RATIONALE Stable isotope analysis of archaeological charred plants has become a useful tool for interpreting past agricultural practices and refining ancient dietary reconstruction. Charred material that lay buried in soil for millennia, however, is susceptible to various kinds of contamination, whose impact on the grain/seed isotopic composition is poorly understood. Pre-treatment protocols ha...

متن کامل

Stable isotope analysis of human hair and nail samples: the effects of storage on samples.

When submitting samples for analysis, maintaining sample integrity is essential. Appropriate packaging must be used to prevent damage, contamination or loss of sample. This is particularly important for stable isotope analysis by isotope ratio mass spectrometry as this technique is capable of detecting subtle differences in isotopic composition with great precision. In a novel study, scalp hair...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 30 13  شماره 

صفحات  -

تاریخ انتشار 2016