Modelling Nonlinear Responses of Resonance Sensors in Pressure Garment Application
نویسندگان
چکیده
Information on the applied pressure is critical to the pressure garment treatment. The use of the passive resonance sensors would be significant improvement to existing systems. These sensors have nonlinear response and thus require nonlinear regression methods. In this paper we compare three nonlinear modelling methods: Sugeno type fuzzy inference system, support vector regression and multilayer perception networks. According to the results, all the tested methods are adequate for modelling an individual sensor. The used methods also give promising results when they are used to model responses of multiple sensors.
منابع مشابه
Modelling of Resonance Frequency of MEMS Corrugated Diaphragm for Capacitive Acoustic Sensors (TECHNICAL NOTE)
In this paper, a new model for resonance frequency of clamped circular corrugated diaphragm has been presented. First, an analytical analyzes has been carried out to derive mathematic expressions for mechanical sensitivity of diaphragm with residual stress. Next by using Rayleigh's method we present mathematical model to calculate the resonance frequency of corrugated diaphragm and investigate ...
متن کاملModelling of Suddenly Expanded Flow Process in Supersonic Mach Regime using Design of Experiments and Response Surface Methodology
The present work is an attempt to model, analyze, and control the flow at the base of an abruptly expanded circular duct by using design of experiments (DOE) and response surface methodology (RSM). Tiny-jets in the form of orifice were positioned at an interval of 900, 6.5 mm from the primary axis of the main jet of the nozzle. Experiments were conducted to measure two responses namely, base pr...
متن کاملVibration Analysis of a Nonlinear System with a Nonlinear Absorber under the Primary and Super-harmonic Resonances (TECHNICAL NOTE)
Abstract In vibratory systems, linear and nonlinear vibration absorbers can be used to suppress the primary and super-harmonic resonance responses. In this paper, the behavior of a nonlinear system with a nonlinear absorber, under the primary and super-harmonic resonances is investigated. The stiffnesses of the main system and the absorber are cubically nonlinear and the dampers are linear. M...
متن کاملEffects of Fluid Environment Properties on the Nonlinear Vibrations of AFM Piezoelectric Microcantilevers
Nowadays, atomic-force microscopy plays a significant role in nanoscience and nanotechnology, and is widely used for direct measurement at atomic scale and scanning the sample surfaces. In tapping mode, the microcantilever of atomic-force microscope is excited at resonance frequency. Therefore, it is important to study its resonance. Moreover, atomic-force microscopes can be operated in fluid e...
متن کاملEquivalent Circuit Models for Micromechanical Inertial Sensors
Numerical simulation models for capacitive, micromechanical inertial sensors are presented. These dynamic, nonlinear models include the contributions of electrical, mechanical, and fluidic energy domains by means of electrical equivalent circuits consisting of lumped, frequency-independent components. The mechanical resonance modes, gap capacitances, gas film damping forces and the electrostati...
متن کامل