Corneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia
نویسنده
چکیده
BACKGROUND The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). METHODS Two sets of measurements were made for 78 eyes of 39 subjects, approximately 1 week apart. In session 1, each eye of each subject was randomized into one of three groups: polyvinyl alcohol (0.5%), tetracaine hydrochloride (0.5%), or oxybuprocaine hydrochloride (0.4%). In session 2, eyes that were in the polyvinyl alcohol group in session 1 were assigned to the tetracaine group, those in the tetracaine group in session 1 were assigned to oxybuprocaine group, and those in the oxybuprocaine group in session 1 were assigned to the polyvinyl alcohol group. For both sessions, each subject first had his or her central corneal thickness assessed with a specular microscope, followed by measurements of intraocular pressure and corneal biomechanical parameters with the Ocular Response Analyzer. All measurements were repeated for 2 minutes and 5 minutes following the instillation of either polyvinyl alcohol, tetracaine, or oxybuprocaine. The level of statistical significance was 0.05. RESULTS Polyvinyl alcohol, tetracaine hydrochloride, and oxybuprocaine hydrochloride had no statistically significant (P > 0.05) effect on any of the biomechanical parameters of the cornea. There was no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) 2 minutes after the eye drops were instilled in either session. Five minutes after the eye drops were instilled, polyvinyl alcohol showed no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) in either session. Oxybuprocaine and tetracaine caused statistically significant (P < 0.05) reductions in IOPg in session 1, but only tetracaine had a significant (P < 0.05) effect in session 2. Tetracaine also caused a statistically significant (P < 0.05) reduction in IOPcc in session 1. CONCLUSION The statistically significant effect of topical anesthesia on IOPg varies with the anesthetic used, and while this effect was statistically significant in this study, the small effect is probably not clinically relevant. There was no effect on any of the biomechanical parameters of the cornea.
منابع مشابه
Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)
Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملStudies on Corneal Permeation and Oculo-Hypotensive Effect of Benazepril in Chronic and Acute Models of Glaucoma
ABSTRACT The present study was carried out to investigate the effect of benazepril on corneal permeation in goat cornea and its effect on experimentally induced acute and chronic glaucoma in rabbits. Acute glaucoma was produced by i.v. infusion of 5% glucose (15ml / Kg) in rabbits, whereas chronic glaucoma was induced by injection of alpha-chymotrypsin into posterior chamber of rabbit eye. We s...
متن کاملApplication of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics
The aim of the present study was to evaluate the effects of femtosecond laser-assisted cataract surgery (FLACS) and phacoemulsification on corneal biomechanics using corneal visualization Scheimpflug technology. The medical records of 50 eyes from 50 patients who received phacoemulsification and intraocular lens implantation because of age-related factors between June 2014 and September 2014 we...
متن کاملEffect of diabetes mellitus on biomechanical parameters of the cornea.
PURPOSE To compare parameters of biomechanical response of the human cornea measured as corneal hysteresis (CH) and corneal resistance factor (CRF) in patients with diabetes mellitus and healthy control subjects. SETTING Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel. METHODS In the right eye of each participant, the CH, CRF, Goldmann-correlated intraocular press...
متن کامل