Predictive Accuracy of Transcerebellar Diameter in Comparison with Other Foetal Biometric Parameters for Gestational Age Estimation among Pregnant Nigerian Women.
نویسندگان
چکیده
OBJECTIVE To compare the predictive accuracy of foetal trans-cerebellar diameter (TCD) with those of other biometric parameters in the estimation of gestational age (GA). DESIGN A cross-sectional study. SETTING The University of Benin Teaching Hospital, Nigeria. SUBJECTS Four hundred and fifty healthy singleton pregnant women, between 14-42 weeks gestation. MAIN OUTCOME MEASURES Trans-cerebellar diameter (TCD), biparietal diameter (BPD), femur length (FL), abdominal circumference (AC) values across the gestational age range studied. Correlation and predictive values of TCD compared to those of other biometric parameters. RESULTS The range of values for TCD was 11.9 - 59.7mm (mean = 34.2 ± 14.1mm). TCD correlated more significantly with menstrual age compared with other biometric parameters (r = 0.984, p = 0.000). TCD had a higher predictive accuracy of 96.9% ± 12 days), BPD (93.8% ± 14.1 days). AC (92.7% ± 15.3 days). CONCLUSION TCD has a stronger predictive accuracy for gestational age compared to other routinely used foetal biometric parameters among Nigerian Africans.
منابع مشابه
Ultrasonographic fetal scapular length measurement for assessment of gestational age
one of the major goals of antenatal care is estimation of gestational age.the most widely used parameters for evaluation of fetal growth are biparietal diameter (BPD),femoral length (FL) and adbominal circumference (AC).to determine the value of prenatal ultrasonographic scapula measurements for fetal growth and gesattional age a prospective ultrasonographic cross-sectional study was conducted ...
متن کاملCerebellar Measurements with Ultrasonography in the Evaluation of Fetal Age
The use of ultrasonography has significantly improved the evaluation of fetal growth and development and has permitted prenatal diagnosis of a variety of congenital malformations.Campbell et al in (1968) studied fetal cephalometry in the second trimester and determined that the fetal head can be measured from 13 week of pregnancy2. BinholzJ.C(1982) studied the new born cerebellar size both in f...
متن کاملNomogram for Foetal Kidney Length
Objective : To evaluate the application and accuracy of foetal kidney length measurement in determining the gestational age of the foetus. Design : Prospective study Methodology : Out of 70 women, 50 women who were certain of their last menstrual periods (LMP) and who had regular menstrual cycle completed the study. Serial study of foetal biometry at 2 weekly intervals between 22 weeks and 38 w...
متن کاملیک روش ساده تخمین وزن جنین با سونوگرافی
Estimating fetal weight in utero, for better management of pregnancy and appropriate timing of delivery especially in high-risk pregnancies is necessary. Our purpose to evaluate a simple method in estimating fetal weight in Iranian pregnant patients and also to compare was with a previous western study. This study was carried out in Arash hospital, Tehran university of medical sciences in 1996-...
متن کاملComparison between transcerebellar diameter with biparietal diameter of ultrasound for gestational age measurement in third trimester of pregnancy.
OBJECTIVE To determine the frequency of correct assessment by transcerebeller diameter (TCD) versus biparietal diameter (BPD) for gestational age measurement at 36 weeks of pregnancy using first day of last menstrual period (LMP) for actual period of gestation. STUDY DESIGN Quasi experimental. PLACE AND DURATION OF STUDY Department of Obstetrics and Gynaecology, Bahawal Victoria Hospital, B...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- East African medical journal
دوره 91 4 شماره
صفحات -
تاریخ انتشار 2014