Comparative Efficacies of Antimicrobial Catheter Lock Solutions for Fungal Biofilm Eradication in an in Vitro Model of Catheter-Related Fungemia
نویسندگان
چکیده
Fungal catheter-related bloodstream infections (CRBSIs)-primarily due to Candida species-account for over 12% of all CRBSIs, and have been progressively increasing in prevalence. They present significant health and economic burdens, and high mortality rates. Antimicrobial catheter lock solutions are an important prophylactic option for preventing fungal CRBSIs. In this study, we compared the effectiveness of two FDA-approved catheter lock solutions (heparin and saline) and three experimental antimicrobial catheter lock solutions-30% citrate, taurolidine-citrate-heparin (TCH), and nitroglycerin-citrate-ethanol (NiCE)-in an in vitro model of catheters colonized by fungi. The fungi tested were five different strains of Candida clinical isolates from cancer patients who contracted CRBSIs. Time-to-biofilm-eradication was assessed in the model with 15, 30, and 60 min exposures to the lock solutions. Only the NiCE lock solution was able to fully eradicate all fungal biofilms within 60 min. Neither 30% citrate nor TCH was able to fully eradicate any of the Candida biofilms in this time frame. The NiCE lock solution was significantly superior to TCH in eradicating biofilms of five different Candida species (p = 0.002 for all).
منابع مشابه
In vitro efficacies of caspofungin or micafungin catheter lock solutions on Candida albicans biofilm growth.
OBJECTIVES Caspofungin and micafungin belong to the echinocandins; the mechanism of action of echinocandins is based on the inhibition of (1,3)-beta-D-glucan synthase. The aim of this study was to investigate in vitro the optimal antifungal lock treatment details against a Candida albicans biofilm. METHODS An in vitro model of a C. albicans (ATCC 3153 or ATCC 66396) biofilm associated with 10...
متن کاملChelator-based catheter lock solutions in eradicating organisms in biofilm.
Two different chelator-based antimicrobial catheter lock solutions, methylene blue-citrate-parabens (MB-CIT) and minocycline-EDTA-25% ethanol (M-EDTA-25% ETOH), were compared in 2-h biofilm eradication experiments. Eradication of both mature and immature Gram-positive, Gram-negative, and fungal biofilms was assessed. M-EDTA-25% ETOH was able to fully eradicate all biofilms within 2 h. MB-CIT wa...
متن کاملIn vitro effectiveness of colistin, tigecycline and levofloxacin alone and combined with clarithromycin and/or heparin as lock solutions against embedded Acinetobacter baumannii strains.
OBJECTIVES To determine the in vitro stability and efficacy of colistin, tigecycline and levofloxacin alone or in combination with clarithromycin and/or heparin as lock solutions against biofilm-embedded Acinetobacter baumannii strains. METHODS Candidate antibiotics (colistin, tigecycline and levofloxacin) were investigated in vitro, either alone or in combination with clarithromycin and/or h...
متن کاملComparison of ML8-X10 (a prototype oil-in-water micro-emulsion based on a novel free fatty acid), taurolidine/citrate/heparin and vancomycin/heparin antimicrobial lock solutions in the eradication of biofilm-producing staphylococci from central venous catheters.
OBJECTIVES Antimicrobial lock solutions are used for prevention and management of catheter-related bloodstream infections. ML8-X10 (a prototype oil-in-water micro-emulsion based on a novel free fatty acid), vancomycin/heparin and taurolidine/citrate/heparin (Taurolock™-Hep500) lock solutions were tested against biofilm-forming Staphylococcus epidermidis and methicillin-susceptible Staphylococcu...
متن کاملIn Vitro Approach for Identification of the Most Effective Agents for Antimicrobial Lock Therapy in the Treatment of Intravascular Catheter-Related Infections Caused by Staphylococcus aureus.
Infection of intravascular catheters by Staphylococcus aureus is a significant risk factor within the health care setting. To treat these infections and attempt salvage of an intravascular catheter, antimicrobial lock solutions (ALSs) are being increasingly used. However, the most effective ALSs against these biofilm-mediated infections have yet to be determined, and clinical practice varies gr...
متن کامل