Comparison of Red Blood Cell Hemolysis Using Plasma and Serum Separation Tubes for Outpatient Specimens

نویسندگان

  • Dae-Hyun Ko
  • Dahae Won
  • Tae-Dong Jeong
  • Woochang Lee
  • Sail Chun
  • Won-Ki Min
چکیده

BACKGROUND To rapidly obtain outpatient results, we use plasma separation tubes (PST) for chemistry analysis. If lactate dehydrogenase measurement is required, serum separation tubes (SST) are used. There has been no evaluation of hemolysis with these tubes. We compared the hemolytic index (HI) obtained by using PST and SST and applied this for choosing appropriate tubes for clinical laboratories. METHODS The HI of specimens obtained from outpatients visiting Asan Medical Center between July and December 2012 was analyzed. The HI was scored from 0 to 10 by using the Toshiba 200FR (Toshiba Medical Systems Co., Japan). HI was classified by sample tube type, and significant hemolysis was defined as a HI of 2 or more. For significant hemolysis cases, medical records were reviewed to identify the causes. RESULTS Among 171,519 specimens, significant hemolysis was observed in 0.66% of specimens (0.68% of PST specimens, 0.46% of SST specimens). The mean HI in PST was 0.18 (SD: 0.43) and that in SST was 0.14 (SD: 0.37). The proportion of significant hemolysis was significantly higher in PST than in SST (P=0.001). The cause of significant hemolysis was identified as chemotherapy and prosthetic valve in 48.1% of specimens. Complex sampling errors may have caused significant hemolysis in the remaining 51.9% of specimens. CONCLUSIONS The incidence of hemolysis was slightly higher for PST than SST, although both were <1%. PST are thought to be more useful than SST in outpatient testing because of rapid turnaround time, greater sample volume, and less risk of random errors due to fibrin strands.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are tubes containing sodium fluoride still needed for the measurement of blood glucose in hospital laboratory practice?

OBJECTIVES To compare glucose values obtained using sodium flouride (NaF) tubes and serum separation tubes (SST) in a tertiary care hospital laboratory setting. METHODS This study was conducted at the Clinical Biochemistry Laboratory, Royal Hospital, Oman. During the study period (1 September-30 November 2013), 50 pairs (one NaF tube and one SST) of patient's blood specimens were randomly col...

متن کامل

Rate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative

Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...

متن کامل

Stability studies of twenty-four analytes in human plasma and serum.

BACKGROUND The stability and stoichiometric changes of analytes in plasma and serum after prolonged contact with blood cells in uncentrifuged Vacutainer tubes were studied. METHODS We simultaneously investigated the stability of 24 analytes (a) after prolonged contact of plasma and serum with blood cells and (b) after immediate separation of plasma and serum (centrifuged twice at 2000g for 5 ...

متن کامل

Evaluation of Blood Storage Lesions in Leuko-depleted Red Blood Cell Units

Background: Red blood cells (RBCs) undergo biochemical and morphologic alterations during storage that are known as the storage lesions causing decreased RBC quality and are correlated with transfusion reactions in certain groups especially in infants and critically ill patients. Microvesicles (MVs) as one of storage lesions may be derived from various cell types and have key roles in several...

متن کامل

Effect of Pneumatic Tube System Transport on Serum and Plasma Enzyme Levels

Pneumatic tube systems of various lengths are routinely used in many hospitals to transport blood collection tubes (serum, plasma, whole blood) to the testing laboratory. The present study evaluated the changes in the levels of enzymes in two different tube system transports within the hospital system. Two tubes of blood, one SST (Serum) tube and one Lithium Heparin (Plasma) tube, were collecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2015