Modelling drainage of the precorneal tear film after a blink.

نویسندگان

  • R J Braun
  • A D Fitt
چکیده

We study the drainage of the precorneal tear film in humans. A fluid dynamic model for the drainage of the aqueous layer is developed that includes the effects of evaporation and gravity. The model may be reduced to a single nonlinear partial differential equation for the thickness of the aqueous layer. The equation is solved numerically and accurate times for film rupture are obtained for physically realistic parameters. The results indicate that although gravity and evaporation are not the most dominant effects in some parts of the film, they can nevertheless materially affect the film drainage process and should therefore be included in models for tear film drainage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A model for wetting and evaporation of a post-blink precorneal tear film.

We examine a fluid dynamic model for the evolution of a precorneal tear film that includes evaporation of the aqueous layer and a wetting corneal surface. Our model extends previous work on the break-up time for a post-blink tear film to include a more realistic model for evaporation. The evaporation model includes the effects of conjoining pressure and predicts the existence of an equilibrium ...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

A new, specular reflection-based, precorneal tear film stability measurement technique in a rabbit model: viscoelastic increases tear film stability.

PURPOSE To develop a safe, noninvasive, noncontact, continuous in vivo method to measure the dehydration rate of the precorneal tear film and to compare the effectiveness of a viscoelastic agent in maintaining the precorneal tear film to that of a balanced salt solution. METHODS Software was designed to analyze the corneal reflection produced by the operating microscope's coaxial illumination...

متن کامل

A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.

PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...

متن کامل

The instilled fluid dynamics and surface chemistry of polymers in the preocular tear film.

Using slit lamp fluorophotometry it was demonstrated that the rate of drainage of a vehicle placed in the eye increased with increasing volume and that polymer solutions increased the thickness of the precorneal tear film (PTF). By increasing the viscosity of the delivery vehicle, (e.g., a hydroxypropylmethylcellulose polymer solutions), the PTF retention of fluorescein could be increased. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Mathematical medicine and biology : a journal of the IMA

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2003