Experience with enoxaparin in patients with mechanical heart valves who must withhold acenocumarol.

نویسندگان

  • I Ferreira
  • L Dos
  • P Tornos
  • I Nicolau
  • G Permanyer-Miralda
  • J Soler-Soler
چکیده

OBJECTIVES To evaluate the incidence of thromboembolic and haemorrhagic events in a cohort of patients with mechanical heart valves who had to withhold acenocumarol and were treated with enoxaparin. DESIGN Observational prospective study. SETTING In hospital; after discharge, and follow up by telephone call. PATIENTS AND METHODS All consecutive patients with mechanical heart valves admitted to the authors' hospital between May 1999 and January 2002 who had to interrupt treatment with acenocumarol and were treated with enoxaparin as an alternative to other methods were enrolled. In each patient, the following characteristics were prospectively determined: the reason for interrupting acenocumarol, demographic data, estimated global risk for thromboembolic events, international normalised ratio before starting enoxaparin treatment, number of days taking enoxaparin, and mean level of anti-Xa activity during treatment. All patients were followed up through clinical history during the hospitalisation and by telephone after discharge to detect thromboembolic events. MAIN OUTCOME MEASURE Presence of thromboembolic or haemorrhagic events. RESULTS 82 patients were identified and followed up for a mean of 2.8 months (range 1.5-3.5 months) after discharge. 61 of them (74%) had one or more associated thromboembolic risk factors. Acenocumarol was interrupted (to perform an invasive procedure in 74 patients and because of haemorrhagic complication in 8) an average of 11.2 days (range 3-40 days). Most patients received the standard enoxaparin dose (1 mg/kg at 12 hour intervals). Mean (SD) anti-Xa activity was 0.58 (0.3) IU/ml (median 0.51). There were 8 minor and 1 major bleeding events during enoxaparin treatment. No thromboembolic complications were clinically detected during hospitalisation or during follow up (95% confidence interval 0% to 3.6%). CONCLUSIONS Enoxaparin may be an effective and relatively safe substitute anticoagulant for patients with mechanical heart valves who must withhold acenocumarol.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

Prosthetic heart valves and pregnancy.

To the Editor: Pregnant women with mechanical heart valves are an ultrahigh-risk group, in whom all anticoagulant options pose maternal and/or fetal risks. It is unclear why the authors of the recent update1 selected 4 studies, neither the most recent nor of the highest quality, to give a warfarin embryopathy rate of 1.6%. This anomaly rate is not supported by evidence in their Table 1 (3.9% of...

متن کامل

Safety and Cost-Effectiveness of Bridge Therapies for Invasive Dental Procedures in Patients with Mechanical Heart Valves

PURPOSE Bridge anticoagulation therapy is mostly utilized in patients with mechanical heart valves (MHV) receiving warfarin therapy during invasive dental procedures because of the risk of excessive bleeding related to highly vascular supporting dental structures. Bridge therapy using low molecular weight heparin may be an attractive option for invasive dental procedures; however, its safety an...

متن کامل

Pregnancy Outcome in Women with Mechanical Prosthetic Heart Valves Treated with Unfractionated Heparin (UFH) or Enoxaparin.

OBJECTIVE This study was carried out to determine the maternal (including thromboembolic and hemorrhagic complications) and fetal outcomes (including miscarriage, stillbirth, baby death, and live birth) in women with mechanical heart valves managed with therapeutic doses of unfractionated heparin (UFH) versus enoxaparin during pregnancy. METHODS This is a prospective comparative, nonrandomize...

متن کامل

Anticoagulation of Pregnant Women With Mechanical Heart Valves

T he management of pregnant women with mechanical heart valves is challenging. Recently, based on small numbers of patients and poor-quality data, correspondence from Aventis Pharmaceuticals Inc has described treatment “failures” and concerns about teratogenicity with the use of the low-molecular-weight heparin (LMWH) enoxaparin. The company issued a “Warning” that enoxaparin should not be used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Heart

دوره 89 5  شماره 

صفحات  -

تاریخ انتشار 2003