The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.

نویسندگان

  • J H Siewerdsen
  • D J Moseley
  • B Bakhtiar
  • S Richard
  • D A Jaffray
چکیده

The influence of antiscatter x-ray grids on image quality in cone-beam computed tomography (CT) is evaluated through broad experimental investigation for various anatomical sites (head and body), scatter conditions (scatter-to-primary ratio (SPR) ranging from approximately 10% to 150%), patient dose, and spatial resolution in three-dimensional reconstructions. Studies involved linear grids in combination with a flat-panel imager on a system for kilovoltage cone-beam CT imaging and guidance of radiation therapy. Grids were found to be effective in reducing x-ray scatter "cupping" artifacts, with heavier grids providing increased image uniformity. The system was highly robust against ring artifacts that might arise in CT reconstructions as a result of gridline shadows in the projection data. The influence of grids on soft-tissue detectability was evaluated quantitatively in terms of absolute contrast, voxel noise, and contrast-to-noise ratio (CNR) in cone-beam CT reconstructions of 16 cm "head" and 32 cm "body" cylindrical phantoms. Imaging performance was investigated qualitatively in observer preference tests based on patient images (pelvis, abdomen, and head-and-neck sites) acquired with and without antiscatter grids. The results suggest that although grids reduce scatter artifacts and improve subject contrast, there is little strong motivation for the use of grids in cone-beam CT in terms of CNR and overall image quality under most circumstances. The results highlight the tradeoffs in contrast and noise imparted by grids, showing improved image quality with grids only under specific conditions of high x-ray scatter (SPR> 100%), high imaging dose (Dcenter> 2 cGy), and low spatial resolution (voxel size > or = 1 mm).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Achieving high-resolution, soft-tissue imaging with cone-beam CT: A two-pronged approach for modulation of x-ray fluence and detector gain

Cone-beam computed tomography (CBCT) presents a highly promising and challenging advanced application of flatpanel detectors (FPDs). The great advantage of this adaptable technology is in the potential for sub-mm 3D spatial resolution in combination with soft-tissue detectability. While the former is achieved naturally by CBCT systems incorporating modern FPD designs (e.g., 200 – 400 um pixel p...

متن کامل

Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

PURPOSE The proliferation of cone-beam CT (CBCT) has created interest in performance optimization, with x-ray scatter identified among the main limitations to image quality. CBCT often contends with elevated scatter, but the wide variety of imaging geometry in different CBCT configurations suggests that not all configurations are affected to the same extent. Graphics processing unit (GPU) accel...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Evaluation of a Physical Based Approach of Scattered Radiation Correction in Cone Beam CT for Non-Destructive Testing Applications

Cone Beam Computerized Tomography (CBCT) enables threedimensional imaging with isotropic resolution. X-ray scatter management is a challenging task for quantitative CBCT imaging : scattered radiation level is significantly high on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artifacts, streaks, and quantification inaccuracies. At...

متن کامل

Bilocular Stafne Bone Defect above And Below the Inferior Alveolar Canal Assessed by Cone Beam Computed Tomography: A Case Report

Stafne bone defect is a bone depression containing salivary gland or fatty soft tissue on the lingual surface of the mandible. The most common location is within the submandibular gland fossa and often close to the inferior border of the mandible. This defect is asymptomatic and generally discovered only incidentally during radiographic examination of the area. Stafne bone defect appears as a w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 31 12  شماره 

صفحات  -

تاریخ انتشار 2004