Accuracy and resolution of THz reflection spectroscopy for medical imaging.
نویسندگان
چکیده
The use of THz radiation as a potential tool for medical imaging is of increasing interest. In this paper three methods of analysis of THz spectroscopic information for diagnosis of tissue pathologies at THz frequencies are presented. The frequency-dependent absorption coefficients, refractive indices and Debye relaxation times of pure water and pure lipids were measured and used as prior knowledge in the different theoretical methods for the determination of concentration. Three concentration analysis methods were investigated: (a) linear spectral decomposition, (b) spectrally averaged dielectric coefficient method and (c) the Debye relaxation coefficient method. These methods were validated on water and lipid emulsions by determining the concentrations of phantom chromophores and comparing to the known composition. The accuracy and resolution of each method were determined to assess the potential of each method as a tool for medical diagnosis at THz frequencies.
منابع مشابه
Time and Frequency Resolved THz Spectroscopy of Micro- and Nano-Systems
Terahertz technology [1], at present a dynamically developing field, was enabled by advances in ultra-short pulse lasers and semiconductor coherent sources in the frequency range of 1–50 THz. The extensive activities are focused on THz optics, spectrally bright sources, and detectors. The terahertz time-domain spectroscopy and terahertz imaging are main fields, where terahertz technology finds ...
متن کاملAttenuated internal reflection terahertz imaging.
We present a terahertz (THz) imaging technique based on attenuated internal reflection, which is ideally suited for the analysis of liquid and biological samples. Inserted in a THz time-domain system, and using a high-resistivity low loss silicon prism to couple the THz wave into the sample, the detection scheme is based on the relative differential spectral phase of two orthogonal polarization...
متن کاملDetection of colon cancer by continuous- wave terahertz polarization imaging technique
We demonstrate a reflective, continuous-wave terahertz (THz) imaging system to acquire ex vivo images of fresh human colonic excisions. Reflection measurements of 5-mm-thick sections of colorectal tissues were obtained using a polarization-specific detection technique. Twodimensional THz reflection images of both normal and cancerous colon tissues with a spatial resolution of 0.6 mmwere acquire...
متن کاملDiagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts
Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 55 16 شماره
صفحات -
تاریخ انتشار 2010