Central corneal thickness: z-ring corneal confocal microscopy versus ultrasound pachymetry.
نویسندگان
چکیده
PURPOSE To compare the repeatability and validity of corneal pachymetry by a corneal confocal microscope with a z-axis adapter (Confoscan 4.0 with z-ring adapter: z-CS4) versus ultrasound (US) pachymetry in the measurement of central corneal thickness (CCT). METHODS CCT in 44 eyes of 44 subjects was determined with z-CS4. Z-CS4 exams were used to estimate the repeatability of thickness measurement by z-ring adapter for this confocal microscope. Intraclass Correlation Coefficient (ICC) between two different z-CS4 users was also determined. CCT in the same 44 eyes was determined with US pachymetry and measurements were compared with z-CS4 CCT. RESULTS Z-CS4 CCT showed high intrainstrument reproducibility (ICC = 0.989; 95%CI 0.982-0.993; P < 0.0001). Mean difference among three CCT consecutive measures, in the same eye, was 0.8 +/- 11.1 microm. High correlation was found between two users (ICC = 0.896; 95%IC 0.830-0.937; P < 0.0001). Z-CS4 CCT showed high correlation with US pachymetry (ICC = 0.921; 95%CI 0.851-0.958; P < 0.0001). Mean corneal thickness determined was statistically different with the two methods (US: 512.6 +/- 65.8 microm; z-CS4: 487.8 +/- 60.1 microm; P < 0.0001). CONCLUSION Z-CS4 seems an accurate, noninvasive and reproducible technique for CCT evaluation and confirms that central cornea is thinner when measured with confocal microscopy compared to ultrasounds.
منابع مشابه
Assessment of central corneal thickness and corneal endothelial morphology using ultrasound pachymetry, non-contact specular microscopy, and Confoscan 4 confocal microscopy
BACKGROUND The aim was to compare the repeatability, reproducibility and inherent precision of ultrasound pachymetry (USP), noncontact specular microscopy (SP-2000P) and the Confoscan 4 confocal microscope (z-ring CS4) in measuring endothelial cell density (ECD), coefficient of variation of cell size (CV), and central corneal thickness (CCT) in normal eyes. METHODS In this prospective study, ...
متن کاملMeasurement of Central Corneal Thickness Using Ultrasound Pachymetry and Orbscan II in Normal Eyes
PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...
متن کاملCornea in Marfan disease: Orbscan and in vivo confocal microscopy analysis.
PURPOSE To investigate corneal thickness, curvature, and morphology with the Orbscan Topography System I (Bausch & Lomb, Inc., Salt Lake City, UT) in patients with Marfan syndrome (MFS) and to study MFS with in vivo confocal microscopy. METHODS This prospective, clinical, comparative case series included 60 eyes of 31 patients with MFS and 32 eyes of 17 control subjects. First, biomicroscopic...
متن کاملComparison of optical and ultrasound central corneal pachymetry.
In 100 eyes of 50 patients central corneal thickness was measured comparing optical to ultrasound pachymetry. With optical pachymetry the values were 1 to 40 micrometer (microns) lower in 64 eyes compared to ultrasound pachymetry. With ultrasound pachymetry the values were 1 to 18 microns lower in 26 eyes compared to optical pachymetry. In 10 cases no difference in pachymetry readings was seen ...
متن کاملIntraoperative Pachymetry Using Spectral-Domain Optical Coherence Tomography during Accelerated Corneal Collagen Crosslinking
PURPOSE To evaluate the role of spectral-domain optical coherence tomography (SDOCT) to measure corneal thickness during accelerated corneal crosslinking (CXL). METHODS Intraoperative pachymetry was performed using SDOCT and ultrasound pachymetry (USP) in 6 eyes of 6 patients with keratoconus. Pachymetry readings were obtained at baseline, after epithelium removal and after 30 minutes of ribo...