The VAXstation 4000 Model 90
نویسندگان
چکیده
The VAXstation 4000 Model 90 is the latest member of the VAXstation product line. Based on the NVAX CPU, the Model 90 was designed as a module upgrade to the VAXstation 4000 Model 60 system. The Model 90 has 2.7 times the CPU performance of the Model 60 and provides base-level, two-dimensional graphics performance of 266,000 vectors per second. It supports up to 128MB of memory, an SCSI-1 bus interface, a TURBOchannel option, a synchronous communication option, and several graphics options. The design team used only programmable devices to implement the new logic designed into the system. In addition, a breadboard provided the basis for logic and software verification.
منابع مشابه
The Design of the VAX 4000 Model 100 and MicroVAX 3100 Model 90 Desktop Systems
The MicroVAX 3100 Model 90 and VAX 4000 Model 100 systems were designed to meet the growing demand for low-cost, high-performance desktop servers and timesharing systems. Both systems are based on the NVAX CPU chip and a set of VLSI support chips, which provide outstanding CPU and I/O performance. Housed in like desktop enclosures, the two systems provide 24 times the CPU performance of the ori...
متن کاملThe Hermod behavioral synthesis system
Hermod is an interactive behavioral synthesis program developed at Stanford University. Using a combined control and data flow graph (C/DFG) as an intermediate representation, Hermod generates functional blocks and their interconnection from L -havioral descriptions. Hermod supports a menu-driven interface, displaying the control and data flow graph with a set of legitimate dming-cus and its ha...
متن کاملThe Role of Demand Response in Default Service Pricing
Contact Information a Galen Barbose, MS 90-4000, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley CA 94720, U.S.A., Tel: 1-510-495-2593, email: [email protected] b Charles Goldman (primary contact), MS 90-4000, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley CA 94720, U.S.A., Tel: 1-510-486-4637, email: [email protected] c Bernie Neenan, Neenan Associates, A U...
متن کاملComparison between two shock wave regimens using frequencies of 60 and 90 impulses per minute for urinary stones
PURPOSE Two different regimens of SWL delivery for treating urinary stones were compared. METHODS Patients with urinary stones were randomly divided into two groups, one of which received 3000 shocks at a rate of 60 impulses per minute and the other of which received 4000 shocks at 90 impulses per minute. Success was defined as stone-free status or the detection of residual fragments of less ...
متن کاملRe: comparison between two shock wave regimens using frequencies of 60 and 90 impulses per minute for urinary stones
Dear Editor, I read with interest the manuscript by Mazzucchi et al. on the comparison between two shock wave regimens using frequencies of 60 and 90 impulses/min for urinary stones. In their study, the authors randomized one group to 3000 impulses at a rate of 60 impulses/min and another group to 4000 impulses at a rate of 90 impulses/min. Their results showed no significant differences in sto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Digital Technical Journal
دوره 4 شماره
صفحات -
تاریخ انتشار 1992