Percutaneous tricuspid valve replacement for a stenosed bioprosthesis.

نویسندگان

  • Philip Roberts
  • Roberto Spina
  • Michael Vallely
  • Michael Wilson
  • Brian Bailey
  • David S Celermajer
چکیده

Percutaneous replacement of the aortic and pulmonic valves has rapidly gained acceptance in clinical practice as a feasible alternative to open valve surgery in patients deemed to be at high operative risk.1,2 Total percutaneous tricuspid valve replacement (TVR), on the other hand, has not yet been documented in humans, although this approach has been described in experimental animals.3 Webb et al4 have recently reported 1 case of TVR, using a valve designed for percutaneous use but inserted through a thoracotomy with direct puncture of the right atrium. We describe a case of percutaneous transjugular TVR with a 22-mm valve in a 28-year-old woman with a history of bioprosthetic tricuspid valve replacement (27-mm Medtronic Mosaic valve, Minneapolis, Minn) at age 19 years for tricuspid endocarditis, who presented 9 years later with progressive New York Heart Association Class III right-sided heart failure caused by severe tricuspid valve stenosis (Figure 1). On transthoracic echocardiography (Figure 2 and Figure 3), her mean tricuspid transvalvular gradient was 16 mm Hg, with mild tricuspid regurgitation. Internal valve diameter was estimated at 21 mm, using 3D transesophageal echo images and knowledge of the internal diameter of her previous tricuspid valve bioprosthesis, from the manufacturer’s specifications. To confirm device sizing, a percutaneous balloon tricuspid valvuloplasty was performed, with good “waisting” of a 20-mm balloon but only transient amelioration of the pressure gradient across the valve. The patient wanted to have children and was keen to avoid anticoagulation or the high risk of a third operation in the future, should she have opted for another bioprosthetic TVR via open surgery. Hence, after institutional ethics approval and informed patient consent, it was decided to proceed with percutaneous TVR. The procedure was performed in the cardiac catheterization laboratory under general anesthesia through the right jugular approach. Under fluoroscopic guidance, a percutaneous Medtronic Melody pulmonary valve was deployed using a 22-mm Ensemble delivery system (Video 1). Transesophageal echocardiography confirmed satisfactory placement of the valve (Figure 4 and Video 2). The Figure 1. Apical 4-chamber view showing the thickened bioprosthetic tricuspid leaflets and right atrial enlargement with septal deviation toward the left atrium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balloon dilatation of a stenosed bioprosthesis in the tricuspid valve position.

Percutaneous balloon dilatation of a stenosed Ionescu-Shiley bioprosthesis in the tricuspid valve position was performed twice in a 19 year old woman. On each occasion there was a considerable improvement in symptoms and haemodynamic function but the effect lasted for only a few months. When the valve was excised it showed no evidence of the previous balloon dilatations.

متن کامل

Balloon Valvuloplasty for Bioprosthetic Tricuspid Valve Stenosis

A 73-year-old woman was admitted to our hospital for a scheduled percutaneous transcatheter balloon valvuloplasty of a stenotic tricuspid bioprosthesis. The patient had a history consistent with exertional dyspnea, abdominal distension, and edema of the lower extremities resistant to diuretic treatment over the previous few months. Forty-three years prior, she underwent aortic valve replacement...

متن کامل

Percutaneous transcatheter valve-in-valve implantation in stenosed tricuspid valve bioprosthesis.

Transcatheter valve-in-valve implantation is a promising treatment option for degenerated bioprosthetic heart valves in high-risk patients.1 Successful percutaneous techniques have been described for pulmonary and aortic valves.2,3 We present the first successful percutaneous tricuspid valve-in-valve implantation. The patient was a fragile 74-year-old woman with chronic obstructive pulmonary di...

متن کامل

Percutaneous valve repair and replacement: challenges encountered, challenges met, challenges ahead.

Percutaneous valve therapy developed initially with aortic valve replacement, described by Andersen et al3 in 1992 in a swine model. These investigators fabricated a stent-mounted bioprosthetic valve and demonstrated that percutaneous implantation is feasible. Bonhoeffer et al4 reported the use of a stent-mounted bioprosthesis for pulmonic valve replacement in 2000. This achievement clearly mar...

متن کامل

Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.

The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2010