Evaluation of jugular foramen nerves by using b-FFE, T2-weighted DRIVE, T2-weighted FSE and post-contrast T1-weighted MRI sequences.

نویسندگان

  • Hasan Aydın
  • Elif Altın
  • Alper Dilli
  • Serdar Sipahioğlu
  • Baki Hekimoğlu
چکیده

PURPOSE To assess the most effective magnetic resonance imaging (MRI) sequence for the visualization of the 9th, 10th, and 11th cranial nerves (glossopharyngeal, vagus, and accessory nerves, respectively) in their intraforaminal/canalicular courses. MATERIALS AND METHODS Balanced fast-field echo (b-FFE), 3D-T2W DRIVE, T2W 2D TSE and post-contrast T1W MRI sequences were all applied and we tried to get the best sequence for the exact assessment of the 9th, 10th, and 11th cranial nerves. Six hundred nerves of 100 patients without symptoms of neurovascular compression were examined using the above sequences. Imaging analysis was graded as: a) nerves analyzed by certainty (score of 2), b) nerves analyzed partially (score of 1), and c) nerves not identified (score of 0). RESULTS In all three nerves, the best sequence for the visualization of the cisternal and intraforaminal course was b-FFE, with 58%, 73%, 62%, and all together 64.3% success in showing the fascicles of the 9th-11th nerves. This sequence with a very short time of repetition, symmetrical and balanced gradient around the echo time allowed very fast imaging and a high signal to noise ratio. T2W TSE sequence was superior to the DRIVE T2W sequence in assessing the cisternal and intraforaminal part of all three nerves. Post-contrast T1W sequence was probably the worst sequence in showing all three nerves. CONCLUSION b-FFE gradient echo MRI sequence with high spatial resolution is the optimal sequence for determining the courses of 9th-11th cranial nerves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cranial Nerve with MRI: Value of Balanced Fast-Field Echo and 3D-Drive Sequences Among the T2 TSE Post- Contrast T1 Sequences

Background/Objective: Our aim was to optimize the most effective MR imaging sequence for visualization of the 12th cranial nerve (hypoglossal nerve) through its cisternal course. Patients and Methods: We applied balanced fast-field echo (B-FFE), 3D-T2 weighted Driven Equilibrium RF Reset Pulse (DRIVE), T2 weighted 2D TSE and post-contrast T1 weighted sequences and tried to find out the best seq...

متن کامل

Magnetic resonance imaging of feline eye

The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...

متن کامل

I-45: Advance MRI Sequences in Pelvic Endometriosis

Background: To assess MRI in diagnosing endometriotic lesions, emphasizing T2*weighted imaging efficacy. Materials and Methods: This prospective study of 48 females (22-38 years, average 29.6) clinically suspected of endometriosis from September 2009 to April 2012. MRI was performed with a 1.5 T imager (Siemens) with a body array coil. T1, T2 and T2* weighted (2D-FLASH) sequences were obtained ...

متن کامل

The clinical value of MRI using single-shot echoplanar DWI to identify liver involvement in patients with advanced gastroenteropancreatic-neuroendocrine tumors (GEP-NETs), compared to FSE T2 and FFE T1 weighted image after i.v. Gd-EOB-DTPA contrast enhancement

BACKGROUND To assess the detection rate of liver lesions in patients with advanced gastroenteropancreatic neuroendocrine carcinomas (GEP-NETs) using echo planar (EP) DWI (diffusion weighted imaging) as compared to standard FSE T2 wi and FFE T1 wi with i.v. (Gd-EOB)-DTPA. MATERIAL/METHODS This prospective single-institution study included 55 patients with liver involvement confirmed by GEP-NET...

متن کامل

T2-weighted three-dimensional fast spin-echo MR in inflammatory peripheral facial nerve palsy.

PURPOSE Our objective was to identify histologically and intraoperatively verified focal nerve thickening of the distal intrameatal segment on three-dimensional fast spin-echo (FSE) T2-weighted MR images as a new diagnostic criterion in patients with inflammatory peripheral facial nerve palsy. METHODS Twenty-two patients with clinically diagnosed unilateral (n = 20) or bilateral (n = 2) infla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 17 1  شماره 

صفحات  -

تاریخ انتشار 2011