Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model

نویسندگان

  • Dong Chen
  • Nicky Bertollo
  • Abe Lau
  • Naoya Taki
  • Tomofumi Nishino
  • Hajime Mishima
  • Haruo Kawamura
  • William R Walsh
چکیده

BACKGROUND Uncemented fixation of components in joint arthroplasty is achieved primarily through de novo bone formation at the bone-implant interface and establishment of a biological and mechanical interlock. In order to enhance bone-implant integration osteoconductive coatings and the methods of application thereof are continuously being developed and applied to highly porous and roughened implant substrates. In this study the effects of an electrochemically-deposited dicalcium phosphate dihydrate (DCPD) coating of a porous substrate on implant osseointegration was assessed using a standard uncemented implant fixation model in sheep. METHODS Plasma sprayed titanium implants with and without a DCPD coating were inserted into defects drilled into the cancellous and cortical sites of the femur and tibia. Cancellous implants were inserted in a press-fit scenario whilst cortical implants were inserted in a line-to-line fit. Specimens were retrieved at 1, 2, 4, 8 and 12 weeks postoperatively. Interfacial shear-strength of the cortical sites was assessed using a push-out test, whilst bone ingrowth, ongrowth and remodelling were investigated using histologic and histomorphometric endpoints. RESULTS DCPD coating significantly improved cancellous bone ingrowth at 4 weeks but had no significant effect on mechanical stability in cortical bone up to 12 weeks postoperatively. Whilst a significant reduction in cancellous bone ongrowth was observed from 4 to 12 weeks for the DCPD coating, no other statistically significant differences in ongrowth or ingrowth in either the cancellous or cortical sites were observed between TiPS and DCPD groups. CONCLUSION The application of a DCPD coating to porous titanium substrates may improve the extent of cancellous bone ingrowth in the early postoperative phase following uncemented arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The nanostructure of an electrochemically deposited hydroxyapatite coating

a r t i c l e i n f o The structure of an implant's coating can significantly affect its physical and chemical properties, and eventually – its clinical performance. In this paper, the nanostructure of an electrochemically deposited hydroxyapatite (EDHA) coating was studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), and high-resolution transmission electron microscopy (HRTE...

متن کامل

Evaluating Osseointegration Into a Deeply Porous Titanium Scaffold: A Biomechanical Comparison With PEEK and Allograft.

STUDY DESIGN This was a biomechanical push-out testing study using a porcine model. OBJECTIVE The purpose was to evaluate the strength of implant-bone interface of a porous titanium scaffold by comparing it to polyetheretherketone (PEEK) and allograft. SUMMARY OF BACKGROUND DATA Osseointegration is important for achieving maximal stability of spinal fusion implants and it is desirable to ac...

متن کامل

In Situ Potentiostatic Deposition of Calcium Phosphate with Gentamicin-Loaded Chitosan Nanoparticles on Titanium Alloy Surfaces

Bone implants must be biocompatible and are usually built to promote osseointegration, e.g. by application of plasma spray calcium phosphate (CaP) coating. The risk of infection and biofilm formation on implant surfaces is a well-known problem. The combination of electrochemically deposited CaP coating with antibiotics may offer significant benefits. Here, we demonstrate an innovative in situ e...

متن کامل

Effect of local TGF-β1 and IGF-1 release on implant fixation: comparison with hydroxyapatite coating

BACKGROUND AND PURPOSE Hydroxyapatite (HA) coating stimulates the osseointegration of cementless orthopedic implants. Recently, locally released osteogenic growth factors have also been shown experimentally to stimulate osseointegration so that bone fills gaps around orthopedic implants. Here, we have compared the effect of local release of TGF-beta1 and IGF-1 with that of hydroxyapatite coatin...

متن کامل

Comparison of Selective Laser Melted Titanium and Magnesium Implants Coated with PCL

Degradable implant material for bone remodeling that corresponds to the physiological stability of bone has still not been developed. Promising degradable materials with good mechanical properties are magnesium and magnesium alloys. However, excessive gas production due to corrosion can lower the biocompatibility. In the present study we used the polymer coating polycaprolactone (PCL), intended...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011