Testing flow diverters in giant fusiform aneurysms: a new experimental model can show leaks responsible for failures.
نویسندگان
چکیده
BACKGROUND AND PURPOSE FDs are the latest, most promising tool to treat giant and complex aneurysms. Currently available experimental aneurysm models do not reproduce the potential clinical difficulties of treating these lesions with FDs. MATERIALS AND METHODS Six large or giant canine fusiform aneurysms were created on the distal carotid arteries of 4 animals. Four of the aneurysms had multiple arterial branches originating from the aneurysm; 2 other aneurysms had all branches clipped at the time of aneurysm construction. Aneurysms were treated with multiple telescoping prototype flow-diverting stents (total of 15 FDs). Angiography was carried out before and immediately after implantation, at 2 weeks, and immediately before sacrifice at 12 weeks. Macroscopic photography of specimens was performed, followed by biopsies of selected regions of the tissue formed on the surface of FDs. RESULTS Technical or device-related difficulties occurred in 2 of 6 aneurysm treatments. Fusiform aneurysms with branches intact remained widely patent (mean angiographic score, 3), whereas aneurysms with clipped branches had only small residua (mean angiographic score, 1) at 12 weeks. The presence of very small defects in neointima formation on the surface of FDs, or leaks, was sufficient for residual filling of the aneurysms, which served as reservoirs to feed branches. CONCLUSIONS Experimental canine fusiform carotid aneurysms may reproduce many of the difficulties associated with the treatment of giant aneurysms and could be appropriate for preclinical testing of FD stents.
منابع مشابه
Flow diverter stents in the treatment of intracranial aneurysms: Where are we?
Flow diverter stents are devices designed to treat complex aneurysms. According to preliminary series published in the literature, treatment of aneurysms with flow diverters is highly efficacious with acceptable morbidity and mortality. Delayed aneurysm ruptures have been reported but mechanisms are actually not completely elucidated. In-stent thrombosis or stenosis was also observed. Indicatio...
متن کاملCompacting a Single Flow Diverter versus Overlapping Flow Diverters for Intracranial Aneurysms: A Computational Study.
BACKGROUND AND PURPOSE Locally compacting the mesh of a flow diverter by a dynamic push-pull technique can accelerate intracranial aneurysm healing. We asked how this deployment strategy compares with overlapping 2 flow diverters for aneurysmal flow reduction. MATERIALS AND METHODS Using a high-fidelity virtual stent placement method, we simulated 3 flow-diverter strategies (single noncompact...
متن کاملThe success of flow diversion in large and giant sidewall aneurysms may depend on the size of the defect in the parent artery.
BACKGROUND AND PURPOSE Flow diverters are designed to occlude aneurysms while preserving flow to jailed arterial branches. We postulated that treatment success depended on the size of the aneurysm ostium or defect in the parent artery. MATERIALS AND METHODS Flow diverter expansion and deformation were studied in silicone tubes with wall apertures of various sizes. Large and giant canine sidew...
متن کاملEvolution of Flow-Diverter Endothelialization and Thrombus Organization in Giant Fusiform Aneurysms after Flow Diversion: A Histopathologic Study.
BACKGROUND AND PURPOSE Treatment of giant fusiform aneurysms with flow diverters has been associated with a relatively high rate of complications. Our goal was to study the evolution of flow-diverter endothelialization and thrombus organization at different time points after flow-diverter treatment in giant fusiform aneurysms to better understand reasons for flow-diverter thrombosis and delayed...
متن کاملReconstructive endovascular treatment of fusiform and dissecting basilar trunk aneurysms with flow diverters, stents, and coils.
BACKGROUND AND PURPOSE Patients with fusiform basilar trunk aneurysms have a poor prognosis. Reconstructive endovascular therapy is possible with modern devices. We describe the clinical presentation, radiologic features, and clinical outcome of 13 patients with fusiform basilar trunk aneurysms treated with flow diverters, stents, and coils. MATERIALS AND METHODS Of the 13 patients, 7 were me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 32 11 شماره
صفحات -
تاریخ انتشار 2011